3-8
Ins talla tion
Electrical
ins talla tion
(continued)
All Units Except European Unlts:
a. 200 VAC or 230 VAC three-phase service: Connect the three input
power leads to terminals Ll , L2, and L3. Connect th,e ground wire
to the terminal marked with the symbol for ground.
b. 200 VAC or 230 VAC single-phase service: Connect the two input
power leads to terminals Ll and L2. Do not use L3. Connect the
ground wire to the terminal marked with the symbol for ground.
Find junction terminal J7, Figure 3.9, and install a jumper
(supplied in the ship-with parts) between the two terminals labeled
1J.
European Units Only:
a. 380-Y VAC three-phase four wire service (three-phase with
neutral): Connect the three input power leads to terminals Ll , l2
and L3. Connect the neutral to terminal N. Connect the ground
wire to the terminal marked with the symbol for ground.
b. 220 VAC single-phase service: Connect the two input power leads
to terminals Ll and N. Connect the ground wire to the terminal
marked with the symbol for ground. Find junction terminal J7,
Figure 3.9, and install a jumper (supplied with the ship-with parts)
between the two terminals labeled 1 J.
5. Replace the electrical cabinet enclosure and secure it with the
captive screw.
6. If the plant electrical system is not grounded, make sure that the
ground wire attached to TBl is secured to a reliable earth ground.
NOTE: Do not energize input electrical power at this time. Connect
input power at the appropriate step in Section 4, Preparation of
equipment.