Troubleshooting
641
10. Locating the faulty channel
1. Turn the circuit breaker off.
2. Unplug the hose from channel No. 1 from the unit.
3. Switch the circuit breaker on and note if the red LED is off or on.
4. If it is off, the problem is in either the No. 1 hose channel or No. 1
gun channel. If the red LED remains on, turn the circuit breaker off,
and repeat steps 2 and 3 with channel No. 2.
5. If the red LED remains on after all channels have been unplugged,
the problem is in the tank channel.
(D No&on Corporation 1094
All Rights Reserved
P/N 106 701A
41-2300SP - l/94