EasyManua.ls Logo

Nordson 2304 - Page 76

Nordson 2304
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-18
Troubleshooting
12. Tank, hose orgun
fails to heat or underheats
(continue@
Figure 6.11-
Connector JIB - J5B.
Problem
Possible Reason
Corrective Action
Refer to
0. Hose and
Failed hose
Replace hose
gun OR
To check (Figure 6.9):
Gun alone not (a) Disconnect hose plug (nonheating
heating;
gun) from applicator
yellow LED
(b) Abnormal resistance reading
*
off, red LED
(power off!) between hose plug pins 3
on
and 5 (RTD) at connector JlA - J5A
Normal = 133 ohms at 70°F (21 “C) to
309 ohms at 400°F (205°C)
AND
(a) Disconnect gun plug (nonheating
gun) from hose
(b) Normal resistance reading (power
off!) between hose plug pins 3 and 5
(RTD) at connector Jl B - J5B (Figure
6.11)
Failed RTD or wiring Replace RTD, repair wiring as
Section 7,
To check (Figure 6.9): required
Section 6
(a) Disconnect hose plug (nonheating
(wiring
gun) from applicator
.
diagrams)
(b) Abnormal resistance reading
(power off!) between hose plug pins 3
and 5 (RTD) at connector JlA - J5A
Normal = 133 ohms at 70°F (21 “C) to
309 ohms at 400°F (205°C)
AND
(a) Disconnect gun plug (nonheating
gun) from hose
(b) Abnormal resistance reading
(power off!) between hose plug pins 3
and 5 (RTD) at connector JlB - J5B
(Figure 6.11)
f=N 106 701A
41-2300SP - l/9.4
0 Nordson Corporation 1994
All Rights Resawed