Fulfill
Retrofit Kit DuraBlue/VersaBlue 25L and 50L Melters
17
Part 1105309A
E 2010 Nordson Corporation
PCA
See Figure 5. The PCA is inside the control box:
Figure 5 PCA board (located inside the control box)
S A potentiometer labeled ”Delay” is for a fill time delay. This delay is
the time duration between the level sensor calling for more adhesive
and when the fill system activates. The delay time prevents the
system from frequently turning on and off. The delay time is preset
from the factory at 60 seconds, but can be adjusted from 0 to 119
seconds. The factory sets the potentiometer at the 12 o'clock
position, sufficient for the majority of applications. For reference, 9
o'clock is 20 seconds and 3 o'clock is 100 seconds.