Questions and Answers

  • M
    Megan FrostAug 17, 2025
    Why is my Nordson Dispenser system overfilled?
    • J
      Jacqueline JonesAug 17, 2025
      If your Nordson Dispenser system is overfilled, it could be due to several reasons. The solenoid may be stuck open, in which case you should clean or replace it. Also, check if the sensor ground wire is not connected and connect it. If the refill board isn't working, replace it if it's defective. Finally, the sensor might not be calibrated properly, so you should calibrate the sensor.
  • D
    David CarterOct 30, 2025
    What to do if my Nordson ProBlue Fulfill Dispenser system is underfilled?
    • D
      Daniel HarrisOct 31, 2025
      If your Nordson Dispenser system is underfilled, there could be several reasons. Here's what you can check: * Ensure there's adhesive in the storage bin; add some if it's empty. * Make sure the unit has power. * Dislodge any adhesive bridging and consider adding an optional vibrator kit if the problem continues. * Inspect for clogs or kinks in the wand, hose, or lid, and replace parts if needed. * Replace a clogged filter sock. * Ensure the lid is closed and the lid switch is working. * Verify sufficient air pressure (minimum 65 psi static, 45 psi operating). Replace the regulator if it's defective. * Check that the level sensor has power (LED should be lit) and the power cord is properly installed. * Repair or replace a bent deflector. * Verify power to the control bo...

Summary

System Overview and Theory

Theory of Operation

Explains how the fill system adds adhesive to the melter tank.

Modes of Operation

Details automatic and manual modes for fill system control.

Installation and Setup

Set Up the Fill System

Guides through connecting inputs/outputs and adjusting parameters.

Test the Fill System

Provides steps to verify the fill system is operating correctly.

Operation and Troubleshooting

Clearing a Refill Alarm

Procedure for clearing refill alarms and resuming operation.

Level Sensor Adjustment and Calibration

Instructions for calibrating the level sensor for accurate filling.

Parts and Specifications

Installation Kit Parts

Lists part numbers for standard and splash-resistant kits.

Fulfill System Specifications

Details technical data like operating temperature and air consumption.

Nordson ProBlue Fulfill Specifications

General IconGeneral
ApplicationPackaging, product assembly
Control SystemTouchscreen Interface
Power Requirements50/60 Hz
ConnectivityEthernet
CertificationsCE, UL
TypeHot melt adhesive dispenser