1
+
Saving current settings
ProBlue Fulfill Integrated Fill System
18
Part 1101094_02
E 2012 Nordson Corporation
Test the Fill System
The melter is shipped from the factory preprogrammed for automatic refill
operation. The factory settings that control the operation of the fill system can
be adjusted to meet specific application requirements. Refer to the previous
procedure, Set Up the Fill System.
To test the system
1. Manually fill the tank with solid adhesive.
2. Ensure that the tank lid is closed.
3. Switch the melter on and wait for the system to reach ready status.
4. Enable the fill system by pressing the fill system enable key.
The green LED turns on indicating that the fill system is enabled.
NOTE: The Fulfill system will not operate until the melter reaches ready
status.
1. Melter switch (on/off)
2. Fill system enable key (on/off)
5. Run your production application.
6. Monitor the frequency and the volume of adhesive delivered to the tank.
To ensure that there is sufficient molten adhesive to supply your
production application, it is preferable to have adhesive delivered to the
tank in small batches (less than
1
/
8
of the tank volume) rather than
infrequent large batches.
NOTE: The level sensor is factory-set and should not require
adjustment. However, if your application requires sensor a djustment,
refer to Level Sensor Adjustment and Calibration under Troubleshooting.
7. (Optional) If adhesive is clogging in the inlet air deflector, remove the
deflector. Refer to Remove the Inlet Air Deflector (Optional).
8. (Optional) If you need to adjust the performance of the fill system, refer to
Set Up the Fill System.
9. When you are satisfied that the fill system is operating correctly, save all
of the current melter settings into memorybysimultaneouslypressingthe
number 1 key and the Setup key.