ProBlue Fulfill Integrated Fill System
17
Part 1101094_02
E 2012 Nordson Corporation
Table 2 Fulfill System Parameters
Parameter Name Values Description
47 Fill Time Delay Default: 60 (seconds)
Range: 0-1000 (seconds)
The continuous time delay (in seconds)
between when a tank low level condition is
detected and when the fill system activates.
The Fill Time Delay s etting prevents the
system from frequently turning on and off.
48 Fill Time Limit Default: 60 (seconds)
Range: 0-1000 (seconds)
The time allowed (in seconds ) for the fill
system to attempt to fill the tank before the refill
alarm is activated.
69 Fulfill
Enable/Disable
Default: 1 (automatic
operation)
or
0 (manual operation)
The Fulfill system can be enabled or disabled
either manually or automatically.
Manual enable/disable can be performed
locally or remotely. Local enable/disable is
through the membrane panel. Remote
enable/disable is through a remote input. Refer
to Table 3.
If the system is set for automatic operation and
the melter ready light is on, then the fill system
will be automatically enabled (on). If the melter
ready light is off, then the fill system will be
disabled (off). For example, if the melter is
placed in standby, the Fulfill system
automatically turns off.
79 Tote Vibrator Timer Default: 10 (seconds)
Range: 0-30 (seconds)
An optional vibrator can be purchased for the
adhesive storage bin (tote). When installed,
this vibrator will activate for the user-specified
time before the fill system activates, and then
will stay on until the level sensor is satisfied.
The vibrator helps prevent adhesive bridging
and ensures consistent adhesive delivery from
thetotetothemelter.
Table 3 Fulfill System Inputs/Outputs
Name Type Description
Refill Alarm Output This output will signal when an F9 alarm occurs. To us e this output,
set one of parameters 40-46 to 11.
Remote
Enable/Disable
Input This input allows remote enabling/disabling of the Fulfill system. To
use this o utput, set one of parameters 30-39 to 30.
Clear Refill Alarm Input This input allows remote clearing of a refill alarm. To use this input, set
one of parameters 30-39 to 29. This is a momentary switch. The reset
will be executed on change-of-s t ate (on to off or off to on).