ProBlue Fulfill Integrated Fill System
8
Part 1101094_02
E 2012 Nordson Corporation
Refill Board
See Figure 4. The refill board is located inside the electrical enclosure. Note
that:
S The FAULT, DELAY, and AIR potentiometer functions are controlled
through parameters. Refer to Set Up the Fill System under Installation
for parameter descriptions.
S A dip switch labeled SW1 is preset at the factory. Positions M1 and
M2 should always be ON.
SW1
XT1
XT2
M1
M2
ON
Figure 4 Refill board (located ins ide the electrical enclosure)
Level Sensor
The level sensor detects the level of adhesive in the melter tank. When the
adhesive falls below the set point, the level sensor sends a signal to the refill
board.
The sensor comes preset from the factory for an average application in which
the adhesive in the tank is typically molten. To adjust the level sensor
settings, refer to Level Sensor Adjustment and Calibration under
Troubleshooting.