Fuel Type | Natural Gas |
---|---|
Flow Rate | 6.6 GPM |
Category | Residential |
Gas Type | Natural Gas |
Maximum Flow Rate | 6.6 GPM |
Type | Tankless |
Maximum BTU Input | 199, 000 BTU/h |
Minimum BTU Input | 15, 000 BTU/h |
Ignition Type | Electronic Ignition |
Venting | Direct Vent |
Warranty | 12-Year Limited Heat Exchanger, 5-Year Limited Parts |
Specifies required clearances for installing the water heater indoors.
Step-by-step guide on securely mounting the water heater unit to a wall.
Outlines the step-by-step process for installing the venting system.
Specifies clearances for non-direct vent terminations to building openings.
Importance of matching gas supply type to the water heater's rating plate.
Ensuring gas regulators are operating properly and providing correct pressure.
Requirements for installing a pressure relief valve, its rating, and discharge.
Instructions for connecting water supply pipes, including material and joint considerations.
Checks and considerations for cold water supply pressure and quality.
Electrical grounding requirements and power supply specifications for the water heater.
Requirements for proper grounding to prevent electrical shock.
Instructions for installing the remote controller and its cord.