Questions and Answers

  • M
    melaniehortonAug 20, 2025
    How to troubleshoot Nortron 21B15M that will not turn on?
    • F
      flemingjeffreyAug 20, 2025
      If your Nortron Furnace won't turn on, check the thermostat, circuit breaker, or fuse. Also, inspect the CONTINUOUS VENTILATION switch, bottom sequencer, and transformer.
  • H
    heather17Aug 22, 2025
    Why is my Nortron Furnace not producing enough heat?
    • J
      jeremiahcooleyAug 22, 2025
      If your Nortron Furnace isn't producing enough heat, potential causes include defective elements or sequencers, the SEASON SELECT switch being set to the MILD position, safety limits opening due to duct obstruction or dirty filters restricting airflow, a defective or incorrectly wired two-stage or outdoor thermostat, or a lack of enough cold air returns in the house.
  • T
    Terry EwingAug 25, 2025
    Why does the motor in my Nortron 21B15M Furnace run continuously?
    • M
      melvin14Aug 25, 2025
      If the motor in your Nortron Furnace runs continuously, check if the CONTINUOUS VENTILATION switch is not on the OFF position, if the thermostat wires are incorrectly attached, the bottom sequencer, or the 24 V Relay.
  • T
    Terri HayesAug 27, 2025
    Why does the breaker on the front panel of Nortron Furnace trip?
    • N
      Nathan HickmanAug 27, 2025
      The breaker on the front panel of your Nortron Furnace trips due to overcurrent on the heating element. Reset the breaker. If the problem continues, it's recommended to call an electrician.
  • B
    Billy UnderwoodAug 28, 2025
    Why is the motor in Nortron 21B15M going on and off in short cycles?
    • L
      Laura BellAug 28, 2025
      If the motor in your Nortron Furnace is cycling on and off too frequently or infrequently, the heat anticipator in the thermostat may be incorrectly set or defective.
  • C
    Christopher JordanAug 30, 2025
    Why the thermostat must be set much higher than desired temperature in Nortron 21B15M?
    • L
      lhansenAug 30, 2025
      If the thermostat needs to be set much higher or lower than the desired temperature in your house when using Nortron Furnace, the thermostat may not be leveled or could be out of calibration.
  • F
    fburtonSep 1, 2025
    Why Nortron Furnace is not producing enough heat?
    • C
      Colton HollandSep 1, 2025
      If your Nortron Furnace isn't producing enough heat, consider these potential causes: one or more defective elements or sequencers, the SEASON SELECT switch set to the MILD position, safety limits opening due to duct obstruction or dirty filters restricting airflow, a defective or incorrectly wired two-stage or outdoor thermostat, or a lack of sufficient cold air returns in the house.
  • P
    pmorrisonSep 2, 2025
    What to do if the motor in Nortron Furnace runs continuously?
    • K
      Kelly KnoxSep 2, 2025
      If the motor in your Nortron Furnace runs continuously, check if the RECIRCULATION MODE switch is not in the OFF position. Also, inspect the thermostat wires for incorrect attachment to the furnace, the bottom sequencer (as the bottom heating element might also remain on), and the 24 V Relay.
  • R
    Ronald BennettSep 4, 2025
    Why does the thermal cut-out open in Nortron Furnace?
    • A
      Angel RobinsonSep 4, 2025
      The thermal cut-out in your Nortron Furnace may open because airflow is reduced due to blocked ductwork or very dirty filters. Ensure that these components are clean and unobstructed.
  • D
    dfrazierSep 6, 2025
    What to do if breaker on front panel trips in Nortron Furnace?
    • M
      Matthew CrossSep 6, 2025
      If the breaker on the front panel of your Nortron Furnace trips, it may be due to overcurrent on the heating element. Reset the breaker. If the problem persists, it is recommended to call an electrician.

Summary

Dimensions

General Requirements and Specifications

Operating Options

Breakers

Installation Notes

Cold Air Return

Details how to attach the cold air return duct to the furnace, including side and bottom mounting options.

Electrical Wiring - Power Supply

Covers power supply requirements for single and three-phase units, including ground conductor attachment.

Connecting and Adjusting the Low Voltage Thermostat

Guide for connecting thermostat wires and setting the heat anticipator for optimal performance.

Use in Mobile Homes

Using Optional Equipment

Two-Stage or Outdoor Thermostat

Using two-stage or outdoor thermostats for furnace control, with specific model considerations.

Air Conditioning

Details on integrating air conditioning with the furnace, including coil placement and airflow.

Electronic Air Cleaners and;or Powered Furnace Humidifiers

Information on using 120V accessories like air cleaners and humidifiers with the furnace.

Interlock Connection

Connecting the electric furnace with other devices like wood furnaces or HRV units.

Wiring Diagrams

Service Parts

Maintenance

Troubleshooting

Warranty

Nortron 21B15M Specifications

General IconGeneral
BrandNortron
Model21B15M
CategoryFurnace
LanguageEnglish

Related product manuals