Questions and Answers

  • A
    Amber BridgesAug 20, 2025
    How to troubleshoot Nortron 21B18M that will not turn on?
    • R
      Richard RodriguezAug 20, 2025
      If your Nortron Furnace won't turn on, check the thermostat, circuit breaker, or fuse. Also, inspect the CONTINUOUS VENTILATION switch, bottom sequencer, and transformer.
  • E
    Eric RoyAug 22, 2025
    Why is my Nortron 21B18M Furnace not producing enough heat?
    • J
      Jerry ValdezAug 22, 2025
      If your Nortron Furnace isn't producing enough heat, potential causes include defective elements or sequencers, the SEASON SELECT switch being set to the MILD position, safety limits opening due to duct obstruction or dirty filters restricting airflow, a defective or incorrectly wired two-stage or outdoor thermostat, or a lack of enough cold air returns in the house.
  • D
    Daniel DouglasAug 25, 2025
    Why does the motor in my Nortron Furnace run continuously?
    • D
      Doris HoffmanAug 25, 2025
      If the motor in your Nortron Furnace runs continuously, check if the CONTINUOUS VENTILATION switch is not on the OFF position, if the thermostat wires are incorrectly attached, the bottom sequencer, or the 24 V Relay.
  • S
    Stacey JohnsonAug 26, 2025
    Why does the breaker on the front panel of Nortron 21B18M Furnace trip?
    • A
      Amanda MclaughlinAug 27, 2025
      The breaker on the front panel of your Nortron Furnace trips due to overcurrent on the heating element. Reset the breaker. If the problem continues, it's recommended to call an electrician.
  • J
    Joshua McdonaldAug 28, 2025
    Why is the motor in Nortron 21B18M Furnace going on and off in short cycles?
    • B
      boylelindaAug 28, 2025
      If the motor in your Nortron Furnace is cycling on and off too frequently or infrequently, the heat anticipator in the thermostat may be incorrectly set or defective.
  • D
    Dr. Monica ArroyoAug 29, 2025
    Why the thermostat must be set much higher than desired temperature in Nortron Furnace?
    • M
      Monica ClarkAug 30, 2025
      If the thermostat needs to be set much higher or lower than the desired temperature in your house when using Nortron Furnace, the thermostat may not be leveled or could be out of calibration.
  • S
    Stephanie AshleyAug 31, 2025
    Why Nortron Furnace is not producing enough heat?
    • A
      audrey98Aug 31, 2025
      If your Nortron Furnace isn't producing enough heat, consider these potential causes: one or more defective elements or sequencers, the SEASON SELECT switch set to the MILD position, safety limits opening due to duct obstruction or dirty filters restricting airflow, a defective or incorrectly wired two-stage or outdoor thermostat, or a lack of sufficient cold air returns in the house.
  • M
    Michelle MckeeSep 2, 2025
    What to do if the motor in Nortron Furnace runs continuously?
    • K
      Kathryn RichardsonSep 2, 2025
      If the motor in your Nortron Furnace runs continuously, check if the RECIRCULATION MODE switch is not in the OFF position. Also, inspect the thermostat wires for incorrect attachment to the furnace, the bottom sequencer (as the bottom heating element might also remain on), and the 24 V Relay.
  • L
    laura50Sep 4, 2025
    Why does the thermal cut-out open in Nortron Furnace?
    • V
      valeriejonesSep 4, 2025
      The thermal cut-out in your Nortron Furnace may open because airflow is reduced due to blocked ductwork or very dirty filters. Ensure that these components are clean and unobstructed.
  • S
    Scott ValenciaSep 6, 2025
    What to do if breaker on front panel trips in Nortron Furnace?
    • J
      John ThompsonSep 6, 2025
      If the breaker on the front panel of your Nortron Furnace trips, it may be due to overcurrent on the heating element. Reset the breaker. If the problem persists, it is recommended to call an electrician.

Summary

INSTALLATION NOTES

ELECTRICAL WIRING - POWER SUPPLY

Requirements for single-phase and three-phase supply wire connections.

CONNECTING AND ADJUSTING THE LOW VOLTAGE THERMOSTAT

Guide for connecting thermostat wires and setting the heat anticipator.

WIRING DIAGRAMS

TROUBLESHOOTING

Nortron 21B18M Specifications

General IconGeneral
BrandNortron
Model21B18M
CategoryFurnace
LanguageEnglish

Related product manuals