D SERIES ELECTRIC FURNACE
FB0004
INSTALLATION AND USER MANUAL
IMPORTANT
: READ AND SAVE THESE INSTRUCTIONS.
MODELS: 21D10, 21D15, 21D18, 21D20, 21D23, 21D25 AND 21D27
M
A
D
E
I
N
C
A
N
A
D
A
F
A
B
R
I
Q
U
É
A
U
C
A
N
A
D
A
30042524B
12575216KHUEURRNH4XHEHFZZZGHWWVRQFD

Questions and Answers

  • B
    Betty BarnesAug 19, 2025
    Why Nortron 21D25 Furnace is not producing enough heat?
    • T
      Tyler HullAug 19, 2025
      If your Nortron Furnace isn't producing enough heat, it could be due to several reasons: * One or more defective heating elements or relays. * The HEAT ACTIVATION switch is set to the LOW position. * Safety limits opening due to duct obstruction or dirty filters restricting airflow. * A defective or incorrectly wired two-stage or outdoor thermostat. * Lack of enough cold air returns in the house.
  • B
    Brittany RiosAug 21, 2025
    Why does the breaker on the front panel of Nortron Furnace trip?
    • W
      wcruzAug 21, 2025
      If the breaker on the front panel of your Nortron Furnace trips, it indicates an overcurrent on the heating element. Reset the breaker. If the problem persists, call an electrician.
  • J
    Jennifer BradyAug 25, 2025
    Why does the motor run continuously on Nortron 21D25 Furnace?
    • V
      Victor MillsAug 25, 2025
      If the motor in your Nortron Furnace runs continuously, check if the thermostat wires are incorrectly attached to the furnace.
  • S
    Sherri JacksonAug 26, 2025
    Why does Nortron Furnace motor go on and off in short cycles?
    • S
      simonjasonAug 26, 2025
      If the motor in your Nortron Furnace cycles on and off too quickly or slowly, the heat anticipator in the thermostat may be incorrectly set or defective.
  • G
    geoffrey15Aug 28, 2025
    Why thermostat must be set higher than desired temperature in Nortron 21D25 Furnace?
    • J
      Jason SanchezAug 28, 2025
      If the thermostat on your Nortron Furnace needs to be set much higher or lower than your desired house temperature, the thermostat may not be leveled or may be out of calibration.
  • N
    nmckeeAug 30, 2025
    How to troubleshoot Nortron 21D25 Furnace that will not start?
    • A
      Anna HernandezAug 30, 2025
      To troubleshoot why your Nortron Furnace won't start, first turn the thermostat to its highest setting. Check if there is 24V present between terminals C and W. If there is, the thermostat is working, and the fault lies within the furnace itself. If there is no voltage, the problem is with the thermostat or its connecting wires.
  • J
    Jennifer JenkinsSep 1, 2025
    What to do if Nortron Furnace will not turn off?
    • J
      Jerry MilesSep 1, 2025
      If your Nortron Furnace won't turn off, set the thermostat to its lowest setting. Check if there is still 24V between terminals C and W. If the furnace continues to run with no voltage, the thermostat is opening properly, and the problem is in the furnace. If voltage is present, the fault is in the thermostat or its wiring.
  • T
    Timothy BrewerSep 3, 2025
    Why does the breaker on my Nortron Furnace keep tripping?
    • A
      Amanda MurphySep 4, 2025
      If the breaker on the front panel of your Nortron Furnace trips, it indicates an overcurrent on the heating element. Reset the breaker. If the problem continues, it is recommended to call an electrician.
  • J
    Joshua BensonSep 5, 2025
    Why Nortron 21D25 Furnace will not turn on?
    • H
      hbarnettSep 5, 2025
      If your Nortron Furnace will not turn on, potential causes include issues with the thermostat, an open circuit breaker or fuse, problems with the motor or capacitor, an open contact in the SPEED SELECTOR switch, a faulty electronic control, or the transformer.
  • T
    Timothy MooreSep 7, 2025
    Why does my Nortron 21D25 Furnace motor run continuously?
    • A
      Anthony ChristianSep 7, 2025
      If the motor in your Nortron Furnace runs continuously, it could be due to thermostat wires being incorrectly attached to the furnace.

Summary

Dimensions

General Requirements and Specifications

Operating Options

Breakers

Installation Notes

Cold Air Return

Details requirements for the cold air return duct attachment.

Electrical Wiring - Power Supply

Covers essential electrical supply connections and wiring standards.

Connecting and Adjusting the Low Voltage Thermostat

Guides on thermostat connection and heat anticipator adjustment.

Using Optional Equipment

Two-Stage or Outdoor Thermostat

Instructions for using advanced thermostat types with the furnace.

Air Conditioning

Explains integration of air conditioning systems with the furnace.

Electronic Air Cleaners and;or Powered Furnace Humidifiers

Information on connecting air quality and humidity accessories.

Interlock Connection

Details on connecting the furnace with other heating devices.

Wiring Diagrams

Service Parts

Maintenance

Troubleshooting

Nortron 21D25 Specifications