B SERIES ELECTRIC FURNACE
FB0002
Broan-NuTone Canada Inc.; Mississauga, Ontario www.broan.ca 877-896-1119
INSTALLATION AND USER MANUAL
IMPORTANT
: READ AND SAVE THESE INSTRUCTIONS.
30042478B
M
ODELS: 21B10M, 21B15M, 21B18M, 21B20M, 21B25M, 21B27M, 83B13, 83B24 AND 83B27
M
A
D
E
I
N
C
A
N
A
D
A
F
A
B
R
I
Q
U
É
A
U
C
A
N
A
D
A
®

Questions and Answers

  • K
    Kelly MorenoAug 20, 2025
    How to troubleshoot Nortron 21B25M that will not turn on?
    • D
      Darrell LittleAug 20, 2025
      If your Nortron Furnace won't turn on, check the thermostat, circuit breaker, or fuse. Also, inspect the CONTINUOUS VENTILATION switch, bottom sequencer, and transformer.
  • C
    Christine SanfordAug 22, 2025
    Why is my Nortron 21B25M Furnace not producing enough heat?
    • E
      Erin DavisAug 22, 2025
      If your Nortron Furnace isn't producing enough heat, potential causes include defective elements or sequencers, the SEASON SELECT switch being set to the MILD position, safety limits opening due to duct obstruction or dirty filters restricting airflow, a defective or incorrectly wired two-stage or outdoor thermostat, or a lack of enough cold air returns in the house.
  • M
    michaelbryantAug 25, 2025
    Why does the motor in my Nortron Furnace run continuously?
    • A
      Amanda RamirezAug 25, 2025
      If the motor in your Nortron Furnace runs continuously, check if the CONTINUOUS VENTILATION switch is not on the OFF position, if the thermostat wires are incorrectly attached, the bottom sequencer, or the 24 V Relay.
  • J
    Jill BrownAug 26, 2025
    Why does the breaker on the front panel of Nortron Furnace trip?
    • C
      Cheryl KimAug 27, 2025
      The breaker on the front panel of your Nortron Furnace trips due to overcurrent on the heating element. Reset the breaker. If the problem continues, it's recommended to call an electrician.
  • O
    Olivia HaynesAug 28, 2025
    Why is the motor in Nortron 21B25M Furnace going on and off in short cycles?
    • I
      Isabel NortonAug 28, 2025
      If the motor in your Nortron Furnace is cycling on and off too frequently or infrequently, the heat anticipator in the thermostat may be incorrectly set or defective.
  • S
    Shannon TaylorAug 30, 2025
    Why the thermostat must be set much higher than desired temperature in Nortron 21B25M?
    • J
      John NavarroAug 30, 2025
      If the thermostat needs to be set much higher or lower than the desired temperature in your house when using Nortron Furnace, the thermostat may not be leveled or could be out of calibration.
  • T
    Tina CastilloAug 31, 2025
    Why Nortron Furnace is not producing enough heat?
    • M
      Mrs. Patricia JacksonSep 1, 2025
      If your Nortron Furnace isn't producing enough heat, consider these potential causes: one or more defective elements or sequencers, the SEASON SELECT switch set to the MILD position, safety limits opening due to duct obstruction or dirty filters restricting airflow, a defective or incorrectly wired two-stage or outdoor thermostat, or a lack of sufficient cold air returns in the house.
  • J
    Jeanne HallSep 2, 2025
    What to do if the motor in Nortron Furnace runs continuously?
    • A
      aliciaporterSep 2, 2025
      If the motor in your Nortron Furnace runs continuously, check if the RECIRCULATION MODE switch is not in the OFF position. Also, inspect the thermostat wires for incorrect attachment to the furnace, the bottom sequencer (as the bottom heating element might also remain on), and the 24 V Relay.
  • K
    Kristina Stewart DVMSep 4, 2025
    Why does the thermal cut-out open in Nortron Furnace?
    • S
      Sheena ThompsonSep 4, 2025
      The thermal cut-out in your Nortron Furnace may open because airflow is reduced due to blocked ductwork or very dirty filters. Ensure that these components are clean and unobstructed.
  • D
    Derrick JonesSep 6, 2025
    What to do if breaker on front panel trips in Nortron Furnace?
    • A
      Andrew ValdezSep 6, 2025
      If the breaker on the front panel of your Nortron Furnace trips, it may be due to overcurrent on the heating element. Reset the breaker. If the problem persists, it is recommended to call an electrician.

Summary

DIMENSIONS

GENERAL REQUIREMENTS AND SPECIFICATIONS

OPERATING OPTIONS

BREAKERS

INSTALLATION NOTES

COLD AIR RETURN

Details on attaching the cold air return duct to the furnace.

ELECTRICAL WIRING - POWER SUPPLY

Requirements for single-phase and three-phase unit power supply wiring.

CONNECTING AND ADJUSTING THE LOW VOLTAGE THERMOSTAT

Guide for connecting thermostat wires and setting the heat anticipator.

USE IN MOBILE HOMES

USING OPTIONAL EQUIPMENT

TWO-STAGE OR OUTDOOR THERMOSTAT

How to use two-stage or outdoor thermostats with the furnace.

AIR CONDITIONING

Information on integrating the furnace with an air conditioning system.

ELECTRONIC AIR CLEANERS AND;OR POWERED FURNACE HUMIDIFIERS

Details on using accessory kits for air cleaners and humidifiers.

INTERLOCK CONNECTION

Connecting the furnace with other devices like wood furnaces.

WIRING DIAGRAMS

SERVICE PARTS

MAINTENANCE

TROUBLESHOOTING

WARRANTY