(3) Input / Output Specification
Items Specifications
Input signals
HD
(Position data HOLD): 1 point
Input circuit DC input, photo-coupler isolation
Input logic Negative logic
Rated input voltage
24VDC
±10%
Rated input current 10mA(24VDC)
ON voltage 10VDC or more
Input
OFF voltage 4VDC or less
Output signals
D0
to
D12
(Position data): 13 points
LP
(Latch pulse: position data reading timing): 1 point
SE
, SE(Sensor disconnected error): 2 points
Output circuit Isolation, photo-coupler open collector output
Output logic
D0
to
D12
,
LP
,
SE
:negative logic
SE:positive logic
Rated load voltage 24VDC(30VDC max.)
Max. load current
D0
to
D12
,
LP
:10mA / point
SE
, SE: 100mA / point
Output
Max. voltage drop
when ON
0.8V
5