NTI – MATRIX
INSTALLATION AND OPERATING INSTRUCTIONS
VERSION DATE: 9-15-10
TABLE OF CONTENTS
1.0 SPECIFICATIONS............................................................................................................................................ 3
2.0 INSTALLATION REQUIREMENTS ................................................................................................................. 4
3.0 VENTING.......................................................................................................................................................... 6
4.0 CONDENSATE DRAIN.................................................................................................................................. 13
5.0 INSTALLING GAS PIPING............................................................................................................................ 14
6.0 BOILER PLUMBING...................................................................................................................................... 16
7.0 DOMESTIC HOT WATER SYSTEM.............................................................................................................. 24
8.0 WIRING .......................................................................................................................................................... 28
9.0 CONTROL SETUP......................................................................................................................................... 33
10.0 MATRIX BLOWER OPERATION ................................................................................................................ 37
11.0 HEAT RECOVERY VENTILATION.............................................................................................................. 39
12.0 LIGHTING BOILER...................................................................................................................................... 44
13.0 TROUBLE SHOOTING................................................................................................................................ 46
14.0 SEQUENCE OF OPERATION..................................................................................................................... 50
15.0 INSTALLATION CHECKLIST...................................................................................................................... 51
16.0 ANNUAL MAINTENANCE AND INSPECTION........................................................................................... 52
17.0 PARTS LIST................................................................................................................................................. 55
HAZARD SYMBOL DEFINITIONS
Danger Sign: Indicates a hazardous situation which, if not avoided, will result
in serious injury or death.
Warning Sign: Indicates a hazardous situation which, if not avoided, could
result in serious injury or death.
Caution Sign plus Safety Alert Symbol: Indicates a hazardous situation which,
if not avoided, could result in minor or moderate injury.
Caution Sign without Safety Alert Symbol: Indicates a hazardous situation
which, it not avoided, could result in property damage.
Notice Sign: Indicates a hazardous situation which, if not avoided could result
in property damage.
®
US Models

Questions and Answers

  • C
    Cory WrightSep 12, 2025
    What to do if my NTI Matrix M100 Boiler displays a Boiler Control Error?
    • C
      Courtney GarciaSep 12, 2025
      If your NTI Boiler displays a Boiler Control Error, first check for an error code on the Boiler Control itself. Then, inspect the control wiring from the Boiler Control to the Fan Control, specifically Pins 17 and 18 on the Fan Control.
  • E
    Erika TaylorSep 14, 2025
    How do I resolve a communication error with HRV on my NTI Matrix M100 Boiler?
    • S
      Steven RochaSep 14, 2025
      To resolve a communication error with the HRV on your NTI Boiler: First, check the wiring connections between the HRV and the Fan Controller. Next, verify the door switch on the HRV is functioning correctly. Finally, cycle power to the appliance.

NTI Matrix M100 Specifications

General IconGeneral
Boiler TypeCondensing
Max. Input (BTU/hr)100, 000
Max. Output (BTU/hr)95, 000
AFUE95%
Heat Exchanger MaterialStainless Steel
NOx Emissions< 20 ppm
Fuel TypeNatural Gas
Efficiency95%