1.0 SPECIFICATIONS..................................................................................................2
1.1 HIGH ALTITUDE OPERATION..................................................................................2
2.0 INSTALLATION REQUIREMENTS ...................................................................2
3.0 VENTING .................................................................................................................4
3.1 VENT PIPE MATERIAL ............................................................................................4
3.3 VENTING RULES AND GUIDELINES .........................................................................7
3.4 VENTING CLEARANCES ..........................................................................................7
4.0 CONDENSATE DRAIN..........................................................................................9
5.0 INSTALLING GAS PIPING...................................................................................9
5.0 INSTALLING GAS PIPING.................................................................................10
5.1 INSTALLATION......................................................................................................10
5.2 TESTING AND SETTINGS ........................................................................................10
6.0 HEATING SYSTEM PIPING...............................................................................12
6.1 PRIMARY LOOP PLUMBING...................................................................................13
6.2 SECONDARY LOOP HEATING SYSTEM ..................................................................16
6.2.1 Multiple Zones using Zone Valves.............................................................16
6.2.2 Multiple Zones using Pumps......................................................................16
6.2.3 Multiple Zones with Different Temperatures............................................17
6.3 DOMESTIC COMBI SYSTEM...................................................................................18
7.0 WIRING..................................................................................................................20
7.1 SIMPLIFIED WIRING CONNECTIONS......................................................................21
7.2 ADVANCED WIRING SYSTEMS..............................................................................22
7.2.1 Multiple 4 wire Zone Valves.......................................................................22
7.2.2 Multiple Zones with Taco Valve controller................................................23
7.2.3 Multiple Zones Pump controller................................................................24
7.2.4 Multiple Temperature Zones with Injection Pumps..................................25
8.0 SENTRY 2100 CONTROLLER ...........................................................................26
9.0 LIGHTING BOILER.............................................................................................30
9.1 INITIAL START-UP.................................................................................................30
9.2 RE-LIGHTING UNIT...............................................................................................30
9.3 TURN OFF BOILER.................................................................................................30
10.0 TROUBLE SHOOTING......................................................................................31
11.0 SEQUENCE OF OPERATION ..........................................................................34
14.0 ANNUAL MAINTENANCE AND INSPECTION............................................36
14.1 COMBUSTION CHAMBER CLEANING...................................................................36
15.0 PARTS LIST.........................................................................................................37
CAUTION:
IT IS THE RESPONSIBILITY OF THE HOMEOWNER TO
KEEP THE VENT TERMINAL CLEAR OF SNOW AND ICE.
Trinity Ti Boiler Only
VERSION DATE: 1-5-2010
Installation and
Operation Instructions
Trinit
y
Ti
This Boiler must be installed by a licensed and trained Heating
Technician; otherwise the warranty of this unit is void. Failure
to properly install this unit could cause damage to property
and injury to occupants possibly resulting in death.

Other manuals for NTI Trinity Ti 200

Questions and Answers

  • J
    Jamie DiazAug 21, 2025
    How to solve burner shutting off too soon on my NTI Boiler?
    • A
      Andrew CraneAug 21, 2025
      If the burner on your NTI Boiler shuts off before reaching the set-point temperature and the burner light goes out, it is due to the reset calculation being used to lower the HI setting. If an OD probe is in use, the HI setting is calculated using the formula in Section 8. Adjust the RES setting as necessary.
  • C
    Cody WoodardAug 22, 2025
    What to do if my NTI Trinity Ti 200 bangs or hisses?
    • E
      Erika RobinsonAug 23, 2025
      If your NTI Boiler bangs or sounds like a kettle while the burner is running, it indicates insufficient flow. Ensure the plumbing matches the manual's diagrams. Check for faulty pumps or stuck end switches. This issue can lead to the boiler overheating.
  • J
    johnsonjuliaAug 25, 2025
    What to do if NTI Trinity Ti 200 will not stay lit?
    • Z
      zsimsAug 25, 2025
      If your NTI Boiler won't stay lit, it indicates a lack of a flame signal. If the burner light on the Sentry is going out, check the condensate drain for blockages and the inlet piping for ingested snow or water. If the flame rod gets wet, it may need replacement. Check for resistance from the flame rod to the ground (it must be an open circuit). Verify proper polarity of line and neutral wiring to the boiler.
  • S
    Sandra FernandezAug 27, 2025
    What does ER6 mean on NTI Boiler?
    • M
      michael75Aug 27, 2025
      If the ER6 error code appears on your NTI Boiler, it indicates a problem in the ignition sequence, possibly due to a faulty igniter, flame sensor, gas valve, or improper line pressure or combustion. Check the ignition sequence to identify the malfunctioning component. Also, check for 24V between terminal B on the terminal block and F1 on the Sentry plug. If not present, a limit has tripped.
  • T
    Toni AlexanderAug 28, 2025
    What to do if ER5 On Display DHW Problem appears on NTI Trinity Ti 200 Boiler?
    • S
      Susan CoxAug 28, 2025
      If you see 'ER5 On Display DHW Problem' on your NTI Boiler, it could mean there isn't enough flow to prevent the boiler from tripping on the limit. Verify a minimum of 6 GPM flow through the boiler and indirect circuit. You can also reduce the indirect Aquastat setting or increase the difference between the Lo Setting and the indirect Aquastat setting. Another possibility is an indirect limit or wiring failure.
  • A
    Amy DiazAug 29, 2025
    What to do if Sentry Controller Locks-up in NTI Boiler?
    • T
      Tanya WatkinsAug 29, 2025
      If the Sentry Controller in your NTI Boiler locks up, it may be due to excessive noise, current, or voltage spikes in the 120V power supply. Check the voltage at the wires going to the A-C-T terminals of the boiler. Check the magnitude of the line voltage power supply. Check the Amp draw of output C1 and Ap (max 3 Amp), and the Amp draw of the control on start-up (max 6 Amps).
  • A
    Alicia ColonAug 31, 2025
    What does ER1 mean on NTI Boiler?
    • I
      iayalaAug 31, 2025
      If 'ER1' is displayed on your NTI Boiler, check if water is dripping on the sensor. You may need to reduce the Hi setting and ensure proper water circulation within the system.
  • N
    nathan18Sep 2, 2025
    Why does NTI Boiler display goes blank?
    • Z
      zbaileySep 2, 2025
      If the display on your NTI Boiler goes blank, check for 120V between terminals L1 and L2 at the Sentry. If 120V is present, turn the power off, remove the line voltage harness from the Sentry, and check for resistance between L1 and L2 of the control; if the circuit is open (O.L), the internal fuse has blown. Check for shorts in wires leading to circulators before replacing the controller. If 120V is not present, check the wiring and for 120V at the source.
  • D
    Dawn BrownSep 4, 2025
    What does ER3 mean on NTI Boiler?
    • D
      David BlairSep 4, 2025
      If 'ER3' is displayed on your NTI Boiler, check the wiring. Note that ER3 will appear if the sensed temperature is less than 32°F. If resetting the power corrects the problem, the Sentry control had locked up.
  • C
    Caitlin WeeksSep 5, 2025
    What does ER2 mean on NTI Trinity Ti 200?
    • B
      Bryan ParkSep 5, 2025
      If 'ER2' is displayed on your NTI Boiler, check the wiring.

Summary

Specifications

Installation Requirements

Venting

Vent Pipe Material

Specifies approved materials for exhaust and air intake piping like PVC and CPVC.

Venting Rules and Guidelines

Provides rules for vent termination location, clearances, and piping slopes.

Venting Clearances

Defines code restrictions for flue gas vent terminal placement relative to windows, doors, and grade.

Condensate Drain

Installing Gas Piping

Installation

Covers gas piping installation requirements, referencing codes and flexible pipe usage.

Testing and Settings

Details line and manifold pressure requirements and gas valve adjustment procedures.

Heating System Piping

Wiring

Advanced Wiring Systems

Details wiring for multiple zones using zone valves, Taco controllers, and injection pumps.

Multiple Temperature Zones with Injection Pumps

Wiring for multiple zones with injection pumps and temperature controllers.

Sentry 2100 Controller

Setting the Sentry 2100

Guides on programming the Sentry 2100 controller via its push buttons and menu options.

Lighting Boiler

Initial Start-up

Outlines steps for initial boiler start-up, including checks for gas, water, and combustion.

Re-lighting Unit

Provides instructions for safely re-lighting the boiler burner, emphasizing safety precautions.

Trouble Shooting

Annual Maintenance and Inspection

NTI Trinity Ti 200 Specifications

General IconGeneral
Efficiency95% AFUE
Fuel TypeNatural Gas or Propane
Heating Capacity200, 000 BTU/h
Modulation Ratio5:1
Heat Exchanger MaterialStainless Steel
Water Connections1" NPT