Lx Series Installation and Operation Instructions Trinity Lx
81
Table 14-4 Alert Codes
Code Description Action/Response
281 Abnormal Recycle: LCI off during Ignition period
282 Abnormal Recycle: Demand off during Drive to Purge Rate
283 Abnormal Recycle: Demand off during Measured Purge Time
284 Abnormal Recycle: Demand off during Drive to Light off Rate
285 Abnormal Recycle: Demand off during Pre-Ignition test
286 Abnormal Recycle: Demand off during Pre-Ignition time
287 Abnormal Recycle: Flame was on during Safe Start check
288 Abnormal Recycle: Flame was on during Drive to Purge Rate
289 Abnormal Recycle: Flame was on during Measured Purge Time
290 Abnormal Recycle: Flame was on during Drive to Light off Rate
291 Abnormal Recycle: Flame was not on at end of Ignition period
292 Abnormal Recycle: Flame was lost during Main Flame Establishing Period
293 Abnormal Recycle: Flame was lost early in Run
294 Abnormal Recycle: Flame was lost during Run
295 Abnormal Recycle: Leakage test failed
296 Abnormal Recycle: Interrupted air flow switch was off during Drive to Purge Rate
297 Abnormal Recycle: Interrupted air flow switch was off during Measured Purge Time
298 Abnormal Recycle: Interrupted air flow switch was off during Drive to Light off Rate
299 Abnormal Recycle: Interrupted air flow switch was off during Pre-Ignition test
300 Abnormal Recycle: Interrupted air flow switch was off during Pre-Ignition time
301
Abnormal Recycle: Interrupted air flow switch was off during Main Flame Establishing Period
302 Abnormal Recycle: Ignition failed due to interrupted air flow switch was off
303 Abnormal Recycle: ILK off during Drive to Purge Rate
304 Abnormal Recycle: ILK off during Measured Purge Time
305 Abnormal Recycle: ILK off during Drive to Light off Rate
306 Abnormal Recycle: ILK off during Pre-Ignition test
307 Abnormal Recycle: ILK off during Pre-Ignition time
308 Abnormal Recycle: ILK off during Main Flame Establishing Period
309 Abnormal Recycle: ILK off during Ignition period
310 Run was terminated due to ILK was off
311 Run was terminated due to interrupted air flow switch was off
312 Stuck reset switch
313 Run was terminated due to fan failure
314 Abnormal Recycle: Fan failed during Drive to Purge Rate
315 Abnormal Recycle: Fan failed during Measured Purge Time
316 Abnormal Recycle: Fan failed during Drive to Light off Rate
317 Abnormal Recycle: Fan failed during Pre-Ignition test
318 Abnormal Recycle: Fan failed during Pre-Ignition time
319 Abnormal Recycle: Fan failed during Ignition period
320 Abnormal Recycle: Fan failed during Main Flame Establishing Period
321 Abnormal Recycle: Main Valve off after 10 seconds of RUN
322 Abnormal Recycle: Pilot Valve off after 10 seconds of RUN
323 Abnormal Recycle: Safety Relay off after 10 seconds of RUN
324 Abnormal Recycle: Hardware flame bias
325 Abnormal Recycle: Hardware static flame
326 Abnormal Recycle: Hardware flame current invalid
327 Abnormal Recycle: Hardware flame rod short
328 Abnormal Recycle: Hardware invalid power
329 Abnormal Recycle: Hardware invalid AC line