Nu-Air Ventilation Systems Inc. - HRV Operating & Installation Manual
Rev. 2.3 Aug. 19, 2014 - 4 -
VENTILATION PERFORMANCE
ENERGY PERFORMANCE
EXT.
STATIC
GROSS AIR FLOW
SUPPLY
NET
POWER
SENSIBLE
APPARENT
PRESSURE
SUPPLY
EXHAUST
TEMP.
AIR FLOW
CONSUMED
RECOVERY
SENSIBLE
in wg (Pa)
cfm (l/s)
cfm (l/s)
ºF (ºC)
cfm (l/s)
Watts
EFFICIENCY
EFFECTIVENESS
0.1 (25)
144 (68)
174 (82)
+32 (0)
64 (30)
50
71
80
0.2 (50)
125 (59)
150 (71)
+32 (0)
96 (45)
80
64
73
0.3 (75)
110 (52)
135 (64)
+32 (0)
116 (55)
90
63
70
0.4 (100)
101 (48)
122 (58)
0.5 (125)
93 (44)
104 (49)
13 (-25)
60 (28)
69
64
82
0.6 (150)
79 (37)
93 (44)
0.7 (175)
64 (30)
86 (41)
0.8 (200)
47 (22)
72 (34)
MODEL: NU145
ELECTRICAL: 120V/1/60 Hz. 100W, 0.9A
This product earned the ENERGY STAR® by meeting strict energy efficiency guidelines set by Natural
Resources Canada and the US EPA. It meets ENERGY STAR requirements only when used in Canada.