NuAire LabGard D NU-543-600 - User Manual

NuAire LabGard D NU-543-600
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
OM0283 Page 1 of 70
LabGard® ES Energy Saver
Class II, Type A2 Laminar Flow
Biosafety Cabinet
Models
NU-543-300/400/500/600
Bench/Console
Operation and Maintenance Manual
July, 2021
Revision 2
NU-543-300 Series E
Nu-543-400/500/600 Series D
Manufactured By:
NuAire, Inc.
2100 Fernbrook Lane
Plymouth, MN 55447
Toll-Free: 1-800-328-3352
In Minnesota: (763)-553-1270
Fax: (763)-553-0459
Question and Answer IconNeed help?

Do you have a question about the NuAire LabGard D NU-543-600 and is the answer not in the manual?

Summary

Safety Instructions

Warranty Information

Installation Instructions

Cabinet Location Guidelines

Guides on selecting an appropriate location for the biosafety cabinet.

Set-Up Instructions

Plumbing and Electrical Services

Electrical Services

Discusses power requirements, circuit protection, and GFCI usage.

Testing Methods and Equipment

Operating the NU-543

FlowGard Control System Overview

Details the functions and features of the FlowGard™ control system.

Front Panel Controls

Standby and Run Modes

Run Mode Operation

Describes the cabinet's operation during the run mode, including warm-up.

Nite Care Mode and Alarms

Standby;Run Mode Alarms

Details visual and audible alarms, their priorities, and silencing procedures.

Operating Guidelines

Unidirectional Airflow and Aseptic Technique

Employing Aseptic Technique

Emphasizes proper aseptic techniques for effective cabinet use.

Hazardous Drug Decontamination

Decontamination Preparation

PPE and preparation steps for hazardous drug decontamination.

Decontamination Procedure

Step-by-step procedure for decontaminating the cabinet.

General Maintenance

Cabinet Decontamination

Warnings and requirements for cabinet decontamination.

Manual Decontamination Steps

Automated Decontamination (Auto Decon)

Cabinet Auto Decontamination Setup

HEPA Filter and Motor Replacement

Filter;Motor Replacement Procedure

Steps for removing and replacing HEPA filters and motors.

Airflow Control System Setup

General Setup and Calibration

Overview of setup and calibration procedures for the airflow control system.

Configuration Parameters

Identifies user and functional parameters for the control system.

Setpoint Parameters Configuration

Airflow Calibration Procedures

Downflow Calibration

Inflow Calibration

Sensor Value Adjustment

Alarm Verification Procedures

HEPA Filter Leak Testing

Supply Filter Leak Test

Procedure for checking the integrity of the supply HEPA filter.

Exhaust Filter Leak Test

Procedure for checking the integrity of the exhaust HEPA filter.

Airflow Smoke Pattern Test

Site Installation Assessment Tests

Airflow or Pressure Alarm Test

Tests airflow and pressure alarms for proper functionality.

Exhaust System Performance Test

Evaluates the performance of canopy exhaust transitions.

Cleanliness Classification Test

Main Control Board Maintenance

Control Board Replacement

Steps for replacing the main control board.

Control Board Reset

Airflow Sensor Maintenance

Troubleshooting and Error Messages

Error Message Troubleshooting Guide

A guide to identify and resolve error messages and alarms.

Option Parameters Configuration

Auto Decontamination Settings

NuAire LabGard D NU-543-600 Specifications

General IconGeneral
BrandNuAire
ModelLabGard D NU-543-600
CategoryLaboratory Equipment
LanguageEnglish