2.3.2. Change Access Level 3 Passcode
The Access Level 3 passcode may be changed from the factory default setting. The Access Level 3 passcode
cannot be the same as the Access Level 2 passcode.
To change the passcode, take the following actions:
1) Enter Access Level 3.
2) Press and hold the ACKNOWLEDGE button for 10 s. The SUPPLY LED will flash rapidly.
3) Press 3. The ACKNOWLEDGE LED and the ALARM ZONES LED will both flash.
4) Press ACKNOWLEDGE button. The ACKNOWLEDGE LED will be off and the ALARM ZONES LED will
illuminate.
5) Enter the new 4-digit Access Level 3 passcode using the buttons numbered 1 ~ 8. Each button press will
cause the following indicators to light:
First button press
Zone 1 TEST FAULT DISABLED
Second button press
Zone 2 TEST FAULT DISABLED
Third button press
Zone 3 TEST FAULT DISABLED
Fourth button press
Zone 4 TEST FAULT DISABLED
6) Press ACKNOWLEDGE button to confirm the passcode.
Note: The ACKNOWLEDGE LED does not flash during this process unless more than 4 passcode numbers
are input.
7) Repeat Steps 5 and 6 to confirm the passcode. The internal sounder will give a double short beep.
Passcode is now changed.
If the two passcodes entered are different:
The internal sounder will give a single long beep.
The Zone indicators will turn off.
A new passcode can be entered.
2.4. Reset Passcodes to Factory Default Settings
If the 4002 is reset to the factory default settings, all configuration settings will be lost.
The default settings for the 4002 are as follows:
Detection zones are latching.
Delay timers are disabled.
Zone dependency (coincidence detection) is disabled.
Access Level 2 passcode is set to 6688.
Access Level 3 passcode is set to 8765.
To reset the 4002 to the factory default settings, including the Access Level passcodes, take the following
actions:
1) In Access Level 1, press and hold RESET. After 10 s, SUPPLY LED will flash rapidly.
2) While holding RESET button, enter 1, then 2, then 3, then 4. The relevant LEDs for buttons 1, 2, 3 and 4
will illuminate. The ACKNOWLEDGE LED will flash.
3) Press ACKNOWLEDGE button to confirm.