The lift must park in the lowest position,
connected to the hydraulic system filled with
approximately 14L oil.
Open leveling screws A1 and A2 (max. 1 turn),
and press the “lowering” button about 5
second.
Lifting the platforms without load to the top-
end position (the platform is unevenly high and
is slightly oblique in the final position, the
cylinder levers are not parallel).
Open the emergency-drain screws N1 and N2
(the lift is lowering to the lowest position)
Close the emergency-drain screws N1 and N2.
Leveling screws A1 and A2
Emergency-drain screws N1 and N2