nVent.com | 11
For the earth connection of the underfloor heating,
you must use the PE terminal on the thermostat or a
separate earth terminal connection bloc.
3.4 PRODUCT SPECIFIC INFORMATION
3.4.1 NRG-TEMP IN COMBINATION WITH
NVENT RAYCHEM T2QUICKNET
HEATING MAT
T2QuickNet heating mats are approved with the
NRG-Temp thermostat working in floor sensor mode.
Be aware that the floor sensor must be installed and
activated for any installation with T2QuickNet.
3.4.2 NRG-TEMP WITH THE NVENT RAYCHEM
T2RED (T2REFLECTA) SELF-REGULATING
CABLE
Self-regulating heating cables have an inrush current
at start up. In order to guarantee the life time of the
thermostat, the maximum load of the self-regulating
application in nominal conditions is limited to 10A.
A 13A self-regulating load will reduce the life time of
the thermostat. Maximum circuit length for T2Red is
100 meter.