pH Resolution | 0.01 pH |
---|---|
pH Accuracy | ±0.01 pH |
Display | LCD |
Temperature Range | 0.0 to 100.0 °C |
Temperature Resolution | 0.1 °C |
Temperature Accuracy | ±0.5 °C |
Power | 4 x 1.5V AAA batteries |
Explains the functions of the keys on the pH 5+, pH 6+, and lon 6+ meters.
Details the various indicators and segments on the meter's Liquid Crystal Display.
Instructions on how to attach and detach the protective rubber armor and stand.
Procedure for opening the battery compartment and inserting new batteries correctly.
Explains the 'LO' annunciator for low battery and the caution for replacement.
Step-by-step guide to connecting the electrode and temperature sensor via BNC and phono connectors.
Procedure for conditioning the pH electrode by soaking it in pH 4 buffer solution.
Steps to power on the meter, perform self-diagnostics, and select measurement mode.
Details calibration options using USA, NIST, or Pb buffer groups and automatic buffer recognition.
Step-by-step guide for performing pH calibration with buffer solutions.
Instructions on how to change the meter's pH buffer group selection (USA, NIST, Pb).
Procedure to reset all stored pH/lon calibration or mV offset values to factory default.
Details on performing 2 or 3 point ion calibration with standard solutions for the lon 6+ meter.
Step-by-step guide for calibrating the lon 6+ meter using ion selective electrodes and standard solutions.
Procedure for calibrating the millivolt (mV) or ORP measurements on the pH 6+ meter.
Instructions for calibrating the temperature measurement function of the meter.
Steps to calibrate the temperature probe, comparing it to a NIST certified thermometer.
Procedure for calibrating temperature without a probe, using manual input or factory default.
Guidance on rinsing probes, powering on, selecting mode, and measuring samples.
Using mV mode for diagnosing ISE or pH electrode condition on the lon 6+ meter.
Instructions on how to freeze the displayed measurement using the HOLD key.
How to deactivate the HOLD function and return to live measurement display.
Guidance on storing, washing, cleaning, and handling pH/ORP and ISE electrodes.
Lists common problems, their causes, and suggested solutions for meter operation.
Detailed specifications for pH, mV, and temperature ranges, accuracy, and features.
Lists available replacement parts and accessories with Eutech and Oakton part numbers.
Details the meter and probe warranty periods and lists exclusions from warranty coverage.
Explains the process for obtaining authorization and returning items for service or replacement.