Commissioning/start-up
NOTE
Sensitive electrical components. Incorrect connection will destroy the unit.
Do not connect the unit to a dimmable power supply.
OASE recommends the use of BioKick (OASE filter starter bacteria):
For the initial start-up
After manual cleaning of the foam filters
After fitting new foam filters
When recommissioning following a storage period/over-wintering
Prior to using filter starter bacteria ("Filter starter"), operate the unit for approx. 24 hours without switching on the UVC
unit. If you do not use filter starter bacteria, commissioning can start directly with the "Fitting connections" step.
How to proceed:
Open the container (Cleaning and maintenance\Opening the container).
Fill the filter starter bacteria (adhere to the attendant instructions for use!).
Close the container (Cleaning and maintenance\Closing the container).
Fit the connections ( Assembly).
Check the firm seating of hoses, cover cap for soiled water drain, clamping ring with safety latch.
Turn the function switch (J 5) to water filtering (40), if it is not already in this position.
Switch on the pond pump.
Only switch on the UVC unit when water is flowing through it. You may have to wait for 24 hours.
Connect power plug to the socket. The UVC unit switches on immediately, the blue LED (J 33) is lit.
Operation
The unit is no longer biologically active at water temperatures below 10 °C. Take the unit out of operation at water tem-
peratures below 8 °C or, at the latest, when freezing temperatures are to be expected.
Normal operating condition: The UVC unit is switched on. The UV-C lamp must be replaced after approx. 8000 operat-
ing hours.
Remedy of faults
Malfunction
Cause
Remedy
No water flow through the re-
turn socket.
Filter pump not switched on.
Switch on the filter pump
Supply lines blocked.
Check supply lines
Function switch not turned to "Filter water"
Turn function switch to „Filter water“
UVC lamp display is not lit
Connection defective or has not been made.
Check connection (power plug, power fuse)
Temperature monitor has switched off the UVC
lamp
Allow the UVC lamp to cool down
UVC lamp defective
Replace UVC lamp
Quartz glass tube not fitted
Fit quartz glass tube
Filtering performance not satis-
factory
Function switch not turned to "Filter water"
Turn function switch to „Filter water“
Unit has not been in operation long enough
Wait a few days/weeks
Water extremely soiled
Excessive fish and animal population
Adhere to the reference value
Foam filters clogged
Clean foam filters
Quartz glass tube soiled
Cleaning the quartz glass tube
UVC lamp is in operation for more than 8000
hours
Replace UVC lamp

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oase FiltoClear Series and is the answer not in the manual?

Oase FiltoClear Series Specifications

General IconGeneral
TypePressurized filter
UV ClarifierIntegrated
Cleaning MechanismBackflush cleaning
Max Pond SizeVaries by model (see Pond Volume)
Max Flow RateVaries by model
InstallationIn-ground or above-ground
Pond VolumeVaries by model
UVC PowerVaries by model
Filter VolumeVaries by model
Inlet ConnectionVaries by model
Outlet ConnectionVaries by model
ModelFiltoClear 6000, FiltoClear 12000
Pump ConnectionVaries by model
UV-C Clarifier OptionIntegrated
DimensionsVaries by model
WeightVaries by model