Wear parts
Foam filters
UVC lamp, quartz glass and O ring for quartz glass
Maintenance and cleaning
Removing/inserting the UVC unit head
WARNING
Possible death or severe injury from hazardous electrical voltage!
Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
Isolate the device (disconnect from the power supply) before carrying out any work on it.
Removing the UVC unit head
E
How to proceed:
Press the blue "Press" button (31) at the UVC unit head (4).
Slightly turn the UVC unit head counter-clockwise.
Carefully pull the UVC unit head out of the filter lid (8).
Inserting the UVC unit head
F
Note!
The O ring (32) on the closure of the UVC water housing (4) is firmly clamped on. Only remove the O
ring when it must be replaced (e.g. when the O ring is porous).
How to proceed:
Carefully insert the UVC unit head (4) into the filter lid.
Turn the UVC unit head clockwise up to the stop.
The blue "Press" button engages (31).
Opening/ closing the container
WARNING
Possible death or severe injury from hazardous electrical voltage!
Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
Isolate the device (disconnect from the power supply) before carrying out any work on it.
Opening the container
G
How to proceed:
Push back safety latch (36).
Press the closing hook (35) inwards.
Open and remove the clamping ring (10).