Water-In Bulkhead
Water Source Line
(1/4” Tubing)
7
Yourcoolercanbeusedwithadirectwaterlineconnectionandltrationsystem.Theltrationsystemcanbeinstalled
prior to the water dispenser or can be installed inside the cabinet behind the door.
1. Locate the Water Inlet Bulkhead at the back of the unit. Remove the plug and insert the water source tubing (1/4”)
into the bulkhead. Ensure the water line is secure.
PREPARING THE WATER SYSTEM FOR USE AS A BOTTLE-LESS (POU) WATER DISPENSER
WATER TUBE CONNECTION/
DISCONNECTION PROCEDURES
Fig. A
NOTE: Do not use water that
is microbiologically unsafe or
of unknown quality without
adequate disinfection before or
after the system
1. To connect, push tube
through collet ring into body.
2. Tube must sit fully past
o-ring.
3. To disconnect, hold collet
ring against body and pull
tube out.