13
[330]
APPROX. WATER
SUPPLY LOCATION
6-7/16
[164]
ELECTRICAL
CONNECTIONS
7/8 [22] DIA. HOLE
FOR ELECTRICAL CONNECTION
40
[1016]
WALL OPENING
40-3/4
[1035]
3-15/16
[100]
19-7/8
[505]
9-7/8
[251]
19-3/4
[502]
19
[483]
WALL OPENING
ELECTRICAL
OUTLET OPTIMUM
LOCATION
(SEE NOTE 4)
FLOOR LINE
CHILLER
JUNCTION BOX
WATER INLET
AND OUTLET
11-5/16
[288]
WALL OPENING
(ALLOW ADDITIONAL DEPTH
FOR WATER AND WASTE LINES)
2-3/32
[53]
1/2
[13]
WALL LINE
5/16[8] DIA. MOUNTING
HOLES 8 EACH SIDE
2
[51]
CHILLER
FRAME ASSY
FURNISHED
1-1/4 TAILPIECE
1/4 OD TUBE
COOLING UNIT
WATER INLET
1-1/2 OR 1-1/4
IPS WASTE
STUB OUT
TO BOTTLE FILLER
DISPENSE FITTING
26-23/32
[679]
24-27/32
[631]
WASTE DRAIN
HEIGHT
4-5/16
[110]
21-7/32
[539]
FRAME
3-1/2
[89]
2-5/32
[55]
8-1/16
[205]
3-1/16
[78]
1-1/2
[38]
5/16[8] DIA. MOUNTING
HOLES 4 TOP AND 4 BOTTOM
NOTES:
RECOMMENDED ADULT HEIGHT INTALLATION SHOWN. ADJUST VERTICAL
DIMENSIONS AS REQUIRED T OCOMPLY WITH FEDERAL, STATE AND LOCAL
CODES.
STOP VALVE, TRAP, PIPE CONNECTOR TO WASTE LINE NOT PROVIDED. SHORT
RADIUS TRAP REQUIRED.
ALL DIMENSIONS ARE IN INCHES. DIMENSIONS IN [ ] ARE IN MILLIMETERS.
115V GROUNDED NORTH AMERICAN DUPLEX REEPTACLE REQUIRED. THIS
DRINKING WATER COOLER IS INTENDED TO BE CONNECTED TO A 20A
MINIMUM GROUND FAULT CIRCUIT INTERRUPTING (GFCI) DEVICE TO MEET
UL REQUIREMENTS.
4 .1 .
2 .
3 .
ELECTRICAL OUTLET
OPTIMUM LOCATION
(SEE NOTE 4)
VERSAFILTER III
(IF APPLICABLE)
APPROX. LOCATION
5
OASIS AQUA POINTE® ELECTRONIC BOTTLE FILLER MODELS MWEBF, MW8EBF, MW12EBF