EasyManua.ls Logo

OBSIDIAN CONTROL SYSTEMS NETRON EN4 - Remote Input

OBSIDIAN CONTROL SYSTEMS NETRON EN4
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
MENU: REMOTE INPUT
The device supports ten remote assignments that can trigger
specific actions like recalling a cue or preset. These events are
recalled using local contact closures, DMX In, or a specific
EtherDMX Universe / Address.
SUB MENU
OPTIONS / VALUES
DESCRIPTION
Cue
1 99
Recall a specific cue number
Cue Mode
Trigger
The cue is activated, and all times and links are
processed even if the contact is opened again
Toggle
The cue is activated, and all times and links are
processed only as long as the contact is closed
Netron Preset
a,b,c,…
Recalls this Netron preset when the contact is
closed
User Preset
1 10
Recalls this user preset when contact is closed
Disable DMX
Stops all DMX output for as long as contact is
closed
Send Value
0 255
Sends specific DMX value on all ports for as
long as contact is closed
Source
disabled
Input is disabled
DMX Port
1 xx
Use DMX Port. Port must be set as Input
ArtNet
Artnet Trigger
sACN
sACN Trigger
Universe
Set Universe for remote trigger
Address
Set DMX Address for remote trigger
DMX Map for Remote Trigger
Inputs can be remotely activated over DMX, ArtNET, or sACN. The input is activated as long
as the DMX value is at the value shown below.
Value
Action
0 10
Idle
11 20
Input 1
21 30
Input 2
31 40
Input 3
41 50
Input 4
51 60
Input 5
61 70
Input 6
71 80
Input 7
81 90
Input 8
91 100
Input 9
101 110
Input 10
111 255
Idle