18
MENU: VIEW AND TEST
This Netron device provides a variety of tools right from the front
display to monitor and test the system. Colors indicate changing
values.
SUB MENU
OPTIONS / VALUE
Description
DMX View
View
Port 1 – 4
View the DMX values of a specific port
Range
From: 1 512
default 1
To: 1 512
default 512
Start Monitor
Start Monitoring Values. Use Encoder to dial to the
desired DMX address. Push Encoder to change
display readout style (Grid, List, Address)
Artnet View
Universe
1 256
View a specific Artnet Universe
Range
From: 1 512
default 1
To: 1 512
default 512
Start Monitor
Start Monitoring Values. Use Encoder to dial to the
desired DMX address. Push Encoder to change
display readout style (Grid, List, Address)
sACN View
Universe
1 256
View a specific sACN Universe
Range
From: 1 512
default 1
To: 1 512
default 512
Start Monitor
Start Monitoring Values. Use Encoder to dial to the
desired DMX address. Push Encoder to change
display readout style (Grid, List, Address)
DMX Port Test
Output
Port 1 4
Send generator values on specific port
All Ports
Send generator values on all ports
Range
From: 1 512
default 1
To: 1 512
default 512
Speed
1 10, Manual
Select the speed of generator
Artnet Test
Universe
1 256
Select Artnet Universe
Range
From: 1 512
default 1
To: 1 512
default 512
Speed
1 10, Manual
Select the speed of generator
sACN Test
Universe
1 256
Select sACN Universe
Range
From: 1 512
default 1
To: 1 512
default 512
Speed
1 10, Manual
Select the speed of generator