EasyManua.ls Logo

OBSIDIAN CONTROL SYSTEMS NETRON EN4 - Connections: EN4 (Front & Rear Panels); Front Connections; DMX Ports Status Indicator LEDs; Rear Connections

OBSIDIAN CONTROL SYSTEMS NETRON EN4
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
CONNECTIONS: EN4 (FRONT & REAR PANELS)
FRONT CONNECTIONS
- (6) 5pin DMX/RDM optically isolated ports
- Ports are bidirectional for DMX In and Output
- Full color OLED display
- Encoder w. Push to Select / Exit Button
DMX PORTS STATUS INDICATER LEDs
Ports
Solid
Blink
Flashing/Strobing
DMX
Error
DMX
DMX In
DMX Lost
DMX
DMX Out Stable
DMX Lost
DMX
Flash on RDM packets
All LEDs are dimmable and can be turned off via the Menu/System/Display menu.
REAR CONNECTIONS
- Seetronic Power In/Thru
- (2) RJ45 network connections (1x POE)
Turn to scroll, push–to–select
OLED Display
5 – Pin DMX/RDM
optically isolated port
Menu return button
Power Out
Power In
RJ45 Network
connection
Fuse
RJ45 Network
connection w/POE
DMX Port Status Indicator LED