NUMERIC DISPLAYS: Range: Resolution:
• Main Time of Day 00:00:00 to 23:59:59 hr:min:sec 1 second
• Dual Time of Day 00:00 to 23:59 hr:min 1 minute
• Dual Time Differential OFF, + 01 to + 23, - 23 to - 01 hr 1 hour
• Watch Countdown Timer 23:59 to 0:00 hr:min 1 minute
• Watch Chrono Lap Time 0:00 to 1:59:59.99 .01 second
(hr:min:sec_.01 sec)
• PC/Mac Countdown Timer 1:59 to 0:00 min:sec 1 second
• Temperature 0 to 140 F (-18 to 60 C) 1 degree
• Altitude Level Sea, EL2 to EL7 1 level
• Depth, Max Depth 0 to 330 FT (100 M) 1 FT (0.1 M )
• Time to Fly 23:50 to 0:00 hr:min* 1 minute
(* starting 10 min after the dive)
• Time to Desaturate 23:50 to 0:00 hr:min* 1 minute
(* starting 10 min after the dive)
NUMERIC DISPLAYS: Range: Resolution:
NORM & GAUG Modes -
• Surface Interval 0:00 to 23:59 hr:min 1 minute
• Dive No. 0 to 24 1
• Elapsed Dive Time 00 to 599 min 1 minute
• FO2 Set Points Air, 21 to 100 % 1 %
• PO2 Value 0.00 to 5.00 ATA .01 ATA
• O2 Saturation 0 to 100 % 1 %
• Dive Time Remaining 0 to 599 min 1 minute
• No Deco Deep Stop Time 2:00 to 0:00 min:sec 1 second
• No Deco Safety Stop Time 5:00 to 0:00 min:sec 1 second
• Safety Stop Run Timer 0:00 to 9:59 min:sec 1 second
• GAUG Dive Run Timer 0 to 599 min 1 minute
• Deco Stop Time 0 to 599 min 1 minute
• Total Ascent Time 0 to 599 min 1 minute
• Violation Countdown Timer 23:50 to 0:00 hr:min 1 minute
FREE Mode -
• Surface Interval (< 1 hr) 0:00 to 59:59 min:sec 1 second
1:00 to 23:59 hr:min 1 minute
• Dive No. 0 to 99 1
• Elapsed Dive Time 0:00 to 9:59 min:sec 1 second
• Countdown Timer 9:59 to 0:00 min:sec 1 second
SPECIFICATIONS (CONTINUED)