Setting Dive Time Remaining (continued) -
• Press Both buttons simultaneously, release when SET: 2
appears (4 seconds).
• Press and release the Front (Advance) button, the Units screen
appears with the set point flashing.
• Press the Front (Advance) button 12 more times.
• The graphic dtr, and Alarm (speaker) and Dive Mode icons
appear with the Dive Time Remaining value flashing
(Fig. 41).
• Press and hold the Side (Select) button to scroll through the
Alarm values in increments of one minute.
• Press the Front (Advance) button to accept the setting and
advance to Set Max PO2 Alarm, or press and hold Both
buttons for 2 seconds to revert to Surface Mode.
TO SET - MAXIMUM PO2 ALARM (while in Surface Mode)
Factory set for 1.60 (ATA), the Maximum PO2 Alarm can be set
to values between 1.20 and 1.60 (ATA) in increments of .1 ATA.
• Press Both buttons simultaneously, release when SET: 2
appears (4 seconds).
• Press and release the Front (Advance) button, the Units screen
appears with the set point flashing.
• Press the Front (Advance) button 13 more times.
• The graphic PO2 and Alarm (speaker) icon appear with the
PO2 value flashing (Fig. 42).
Fig. 41 - Set Dive Time
Remaining Alarm
ATR
O
2
Fig. 42 - Set Max PO2 Alarm
ATR
O
2