EasyManua.ls Logo

OHAUS T51XW User Manual

OHAUS T51XW
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
i
5000 Series Indicators
Instruction Manual
T51XW Indicator
T51P Indicator
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Table of Contents

Other manuals for OHAUS T51XW

Questions and Answers:

OHAUS T51XW Specifications

General IconGeneral
ConnectivityUSB, RS232, Ethernet
Display TypeLCD
Power SupplyAC adapter
Operating Temperature0°C to 40°C
Weighing Unitskg, g, lb, oz
CalibrationExternal calibration
HousingStainless Steel
ProtectionIP54
Application ModesWeighing, Counting, Checkweighing

Summary

1. INTRODUCTION

1.1 Safety Precautions

General safety precautions for equipment operation.

2. INSTALLATION

3. SETTINGS

3.3 Calibration Menu

Accessing and performing calibration procedures like Zero, Span, Linearity.

3.4 Setup Menu

3.4.7 Auto-Tare

3.4.9 Legal for Trade

Setting the indicator for legal trade compliance.

3.5 Readout Menu

3.6 Mode Menu

3.6.6 Dynamic Weighing Mode

Configuring dynamic weighing mode settings.

3.6.7 Check Weighing Mode

Enabling or disabling the Check Weighing mode.

3.7 Unit Menu

3.9 Print1 and Print2 Menus

3.9.4 Print Content Sub-menu

3.10 COM1 and COM2 Menus

3.11.2 External Input

3.11.4 Relay Output

Configuring relay output parameters.

3.11.5 End I-O

3.12 Menu Lock Menu

Preventing unauthorized changes to menu settings.

3.12.2 Lock Calibration

Locking the Calibration menu settings.

3.12.3 Lock Setup

3.12.4 Lock Readout

Locking the Readout menu settings.

3.12.5 Lock Mode

Locking the Mode menu settings.

3.12.6 Lock Unit

Locking the Unit menu settings.

3.12.7 Lock Print1

Locking the Print 1 menu settings.

3.12.8 Lock Print2

Locking the Print 2 menu settings.

3.12.9 Lock COM1

Locking the COM1 menu settings.

3.12.10 Lock COM2

Locking the COM2 menu settings.

3.12.11 Lock GMP

3.12.12 Lock I-O

Locking the I-O menu settings.

3.13 Key Lock Menu

Preventing unauthorized access to button functions.

3.13.2 Lock All Buttons

3.13.3 Lock Off Button

Locking the Off button.

3.13.4 Lock Zero Button

Locking the Zero button.

3.13.5 Lock Print Button

Locking the Print button.

3.13.6 Lock Unit Button

Locking the Unit button.

3.13.7 Lock Function Button

Locking the Function button.

3.13.8 Lock Mode Button

Locking the Mode button.

3.13.9 Lock Tare Button

Locking the Tare button.

3.13.10 Lock Menu Button

Locking the Menu button.

4. OPERATION

4.2 Zero Operation

How to perform zero operations under various conditions.

4.3 Manual Tare

How to tare a container or weight.

4.5 Auto-Tare

4.8 Application Modes

Overview of available application modes.

4.8.1 Weighing

4.8.2 Parts Counting

Using the parts counting mode for accurate measurements.

4.8.3 Percent Weighing

Measuring sample weight as a percentage of a reference.

4.8.4 Check Weighing

4.8.5 Dynamic Weighing

Weighing moving or oversized objects.

5. SERIAL COMMUNICATION

6. LEGAL FOR TRADE

6.1 Settings

Steps to perform before verification and sealing.

6.2 Verification

Procedure performed by officials for verification.

6.3 Sealing

Applying security seals to prevent tampering.

7. MAINTENANCE

7.3 Troubleshooting

Common symptoms, causes, and remedies for issues.

Related product manuals