74 Appendix B: Menu Selections
Emulation Mode. IBM PPR (factory default), Epson FX, or ML. Selects the Printer com-
mand set you want your printer to use: IBM Proprinter III, Epson FX, or OKI Microline.
ESC SI Pitch. Designate the function of ESC SI command to 17 cpi setting (default) or
20 cpi setting.
Form Tear-Off. Off (factory default), 500 ms, 1 sec, or 2 sec. Form Tear-Off advances
the paper to the perforation so that you can tear off a sheet of continuous-forms pa-
per. You can turn this feature off, or you can select a time interval for the printer to
wait before advancing the paper.
Graphics. Uni-directional (factory default) or bi-directional. Bi-directional graphics
print faster than uni-directional graphics, but uni-directional graphics have better
print registration. Bi-directional graphics printing can be optimized by adjusting the
Print Registration setting in the Menu.
I-Prime. Buffer Print (factory default), Buffer Clear, or Invalid. Determines how the printer
will react to the I-Prime signal from your software. With the factory default engaged,
when the printer receives the I-Prime signal, it will print out the contents of the buffer
before resetting. Change the setting to Buffer Clear if you wish the printer to dump the
contents of its buffer immediately upon receiving the I-Prime signal. Change to Invalid if
you want the printer to ignore your software’s I-Prime signal. This will permit you to
enter settings through the printer’s control panel which will not be automatically over-
ridden by the software’s settings when the I-Prime signal is sent.
Language Set. American (factory default), French, German, British, Danish I, Swed-
ish, Italian, Spanish I, Japanese, Norwegian, Danish II, Spanish II, Latin American,
French Canadian, Dutch, or Publisher. Replaces certain symbols with special charac-
ters used in the respective foreign languages.
Line Spacing. 6 lpi (factory default) or 8 lpi. Choose 8 lines per inch for tighter line
spacing, to get more lines per page.
Operator Panel Function. Full Operation (factory default) or Limited Operation.
Change to Limited Operation to deactivate the PRINT QUARITY and CHARACTER
PITCH buttons on the control panel. Then you can control these features only through
your software. This can be useful when several people are using the printer and you
don’t want its settings changed.
Important!
This feature also prevents access to the Menu. To access the Menu, turn
the printer off, then hold down the SEL key while turning on the printer.