Maintain a minimum 2-inch airspace to combustibles; 18-inches for single wall connector pipe.
Chimney must terminate at least 3 feet above roof penetration and 2 feet higher than nearby structures.
Use a plumb bob to mark and cut the rough opening in the ceiling for support.
Secure the ceiling support box into the rough opening, ensuring it extends below the ceiling.
Frame openings for multi-story installations, passing through additional ceilings.
Locate and cut the roof opening, ensuring minimum 4-inch clearance.
Install attic insulation shielding to maintain 2-inch airspace from debris and wiring.
Secure chimney sections using self-drilling screws, ensuring proper height termination.
Install flashing, storm collar, and rain cap, maintaining clearances and ensuring a watertight seal.
Install chimney using cathedral ceiling support, extending below the ceiling and potentially above the roof.
Locate the appliance between wall studs according to manufacturer's instructions.
Complete termination based on enclosure type, ensuring proper height and clearance.
Recommends annual inspection and cleaning of the entire chimney system for safety and warranty.