Do you have a question about the Olympus AFU-100 and is the answer not in the manual?
Brand | Olympus |
---|---|
Model | AFU-100 |
Category | Water Pump |
Language | English |
Defines the purpose of the AFU-100 peristaltic pump unit for irrigation and cleansing in endoscopic procedures.
Emphasizes reviewing instructions for safe and effective use of the pump and related equipment.
Specifies that users must be physicians or trained medical personnel under physician supervision.
Advises checking compatibility with ancillary equipment to prevent injury or damage.
States the unit contains no user-serviceable parts and prohibits disassembly or modification.
Explains the meaning of DANGER, WARNING, CAUTION, and NOTE signal words used in the manual.
Introduces general safety precautions, including improper use and the importance of user training.
Lists and explains symbols found on the front, rear panels, packaging, and pump tube.
Details the components, buttons, indicators, and displays on the front panel of the unit.
Describes the connectors and controls located on the rear panel of the peristaltic pump unit.
Explains the function and connection of the optional footswitch for controlling pump flow.
Discusses the pump tube's role in flow rate and its specifications.
Provides instructions for safely installing the peristaltic pump unit on a stable surface.
Details the procedure for attaching and detaching the pump head to the unit.
Guides on how to safely connect the unit to a grounded power outlet.
Explains the purpose of equipotential bonding for increased electrical safety.
Describes how to connect the footswitch plug to the unit's rear panel connector.
Outlines how to connect the pump unit to an electrosurgical unit for system operation.
Details how to turn on the unit, the self-test procedure, and initial setup.
Explains the various audible signals and how to adjust their volume.
Provides step-by-step instructions for inserting and connecting the sterile pump tube.
Guides on selecting the appropriate flow level based on the procedure and pump tube.
Explains how to use memory buttons to store and retrieve frequently used flow levels.
Describes how to start and stop the pump flow using buttons or footswitch.
Outlines the steps to follow after completing an operation, including switching off and cleaning.
Provides detailed instructions for cleaning and disinfecting the peristaltic pump unit and its components.
Advises on proper storage conditions for the unit and pump tube packages to prevent damage.
Guides on the proper disposal of the unit and its components according to regulations.
Lists error codes displayed on the unit and provides corresponding measures or troubleshooting steps.
Mandates annual safety checks for the pump unit and footswitch by authorized personnel.
Instructs users on the procedure for returning the unit for repair, including necessary information.
Presents a graph showing flow rates for different pump tube inner diameters versus flow level.
Lists detailed technical specifications for the unit, including dimensions, power, and compatible units.
Provides guidance on electromagnetic emissions and the manufacturer's declaration for the unit.
Details guidance on electromagnetic immunity and the manufacturer's declaration for the unit.
Provides recommended separation distances for RF communication equipment to maintain EMC.