Do you have a question about the Omega Engineering Rercorder RD8300 and is the answer not in the manual?
Brand | Omega Engineering |
---|---|
Model | Rercorder RD8300 |
Category | Recording Equipment |
Language | English |
Critical safety warning about protective earth terminal interruption.
Notes on disconnecting devices and safety standard compliance.
Describes the ¼ VGA color display, touch screen, task bar, and live display.
Details the AC power input, DC output option, and battery disconnect.
Describes analog input modules, voltage/frequency inputs, and isolation.
Explains saving, loading, and structure of recorder configuration files.
Defines Administrator, Manager, and User privileges for recorder access.
Explains passwords for USB, HTTP, and FTP remote access.
Configures the recorder to start recording when an alarm condition occurs.
Sets up recording to start based on external digital input triggers.
Describes configuring the recorder's 18 channels: analog, digital, and virtual.
One-stop window for setting up all channels, enabling overview and editing.
Configures linear voltage and current inputs, including ranges, span, offset, and filter.
Configures inputs for square root calculations, typically for flow measurements.
Explains setup for thermocouple/RTD types and ambient compensation.
Configures timers controlled by logic points, with reset and alarm options.
Configures frequency inputs, scaling, edge trigger, and filtering.
Provides overview of alarms, channel selection, and master enable settings.
Adjusts thermocouple readings to compensate for ambient temperature variations.
Adjusts basic unit settings: Unit Tag, NTP time server, Modbus, etc.
Using web browser for real-time status, file upload/download via HTTP/FTP.
Guidelines for handling and cleaning the touch screen display.
How to clean the unit, front panel, and display using soft cloths.
Recommendation for annual calibration to ensure maximum accuracy.
Selects channel and range for calibration, displays success message.
Calibrates analog converter offsets by applying 0 Volts.
Calibrates full scale ranges by applying specified input voltages.
Zeros RTD inputs and calibrates the current source on any channel.
Calibrates the RTD current excitation source using a precision resistor.