9
SECURE MENUSECURE MENU
SECURE MENUSECURE MENU
SECURE MENU
Hold
UP ARRUP ARR
UP ARRUP ARR
UP ARR
OO
OO
O
W W
W W
W &
ENTERENTER
ENTERENTER
ENTER for 5 Seconds to display the Secure menu. Press
INDEXINDEX
INDEXINDEX
INDEX to
change the low er displa y. Press
UP ARRUP ARR
UP ARRUP ARR
UP ARR
OO
OO
O
W W
W W
W or
DODO
DODO
DO
WN ARRWN ARR
WN ARRWN ARR
WN ARR
OO
OO
O
W W
W W
W to change the v alue in the
upper display. Press
ENTERENTER
ENTERENTER
ENTER to store the v alue .
SelectionsSelections
SelectionsSelections
Selections
SECrSECr
SECrSECr
SECr Security Code: See the Security Le vel Selection and the Passw ord Ta b le in this
m a n ual, in order to enter the correct pass w ord.
InPInP
InPInP
InP Input Type: Select one of the follo wing. The Inputs are based on four diff erent g roups;
Thermocouples, RTDs, Current, and V oltage . If changing from one of these groups,
the DIP switch on the A/D circuit board will have to be changed to match that
par ticular g roup. Ref er to the Input wir ing section f or the proper switch settings .
J-ICJ-IC
J-ICJ-IC
J-IC Type “J” Thermocouple, Iron/Constantan (NIST)
CACA
CACA
C A Type “K” Ther mocouple CH ROMEGA®/ALOMEGAŠ
E-E-
E-E-
E- Type “E” Thermocouple CH ROMEGA/Constantan
t-t-
t-t-
t- Type “T” Ther mocouple Copper/Constantan
L-L-
L-L-
L- Type “L” Ther mocouple Iron/Constantan (DIN)
n-n-
n-n-
n- Type “N” Thermocouple Nicrosil/Nisil
rr
rr
r
-13-13
-13-13
-13 Type “R” Ther mocouple Pt 13%Rh/Pt
S-10S-10
S-10S-10
S-10 Type “S” Thermocouple Pt 10%Rh/Pt
b-b-
b-b-
b- Type “B” Ther mocouple Pt 6%Rh/Pt 30%Rh
C-C-
C-C-
C- Type “C” Ther mocouple W 5%Re/W 26%Re
P392P392
P392P392
P392 100 ohm Platinum (NIST 0.00392 Ω/Ω/°C)
n120n120
n120n120
n120 120 ohm Nickel (NIST 0.006 Ω/Ω/°C)
P385P385
P385P385
P385 100 ohm Platinum (DIN 0.00385 Ω/Ω/°C)
CurrCurr
CurrCurr
Curr DC Current Input 0.0 to 20.0 or 4.0 to 20.0 milliamperes.
VV
VV
V
oLtoLt
oLtoLt
oLt DC V oltage Input 0.0 to 5.0 or 1.0 to 5.0 v olts.
--
--
-
--
--
-
--
--
-
--
--
- For Access to Calibration and FA Ct dFLt.
OSUPOSUP
OSUPOSUP
OSUP Zero Suppression: Select
OnOn
OnOn
On or
OFFOFF
OFFOFF
OFF. Only with Current and V oltage input types .
OFFOFF
OFFOFF
O F F The input r ange will star t at 0 (z ero) Input.
OnOn
OnOn
O n The input r ange will star t at 4.00 mA or 1.00 V.
UnitUnit
UnitUnit
Unit F, C or None
FF
FF
F °F descr iptor is On and temper ature inputs will be displa yed in actual
degrees Fahrenheit.
CC
CC
C °C descriptor is On and temperature inputs will be displa yed in actual
degrees Celsius .
nonEnonE
nonEnonE
nonE °F and °C descr iptors will be Off . This is only a vailab le with Current and
Voltage Inputs .
dPtdPt
dPtdPt
dPt Decimal Point Positioning: Select
0 0
0 0
0,
0.0 0.0
0.0 0.0
0.0 ,
0.000.00
0.000.00
0.00 , or
0.000 0.000
0.000 0.000
0.000 .
On temperature type inputs
this will only effect the Process Value, SP1, SP2, ALLo, ALHi, and InPC. For Current
and Voltage Inputs all Men u Items related to the Input will be aff ected.
00
00
0 No decimal Point is selected. This is a vailab le f or all input types .
0.00.0
0.00.0
0.0 One decimal place is availab le for Type J, K, E, T, L, RT D s , Current and
Voltage Inputs .
0.000.00
0.000.00
0.00 Tw o decimal places is only availab le for Current and Voltage Inputs.
0.0000.000
0.0000.000
0.000 Three decimal places is only availab le for Current and Voltage inputs .
InPtInPt
InPtInPt
InPt Input Fault Timer: Select
OFFOFF
OFFOFF
OFF
,,
,,
,
0.1 0.1
0.1 0.1
0.1 to
540.0 540.0
540.0 540.0
540.0 minutes. Whenever an input is out of
range, shor ted, or open the timer will star t. When the time has elapsed, the controller
will revert to a saf e condition (Outputs Off, Flashing Displa ys). If OFF is selected, the