69
Note: Factory presets are permanent and cannot be written over. You must use the ā€˜saveas’ command when
saving changes made to a factory preset in order to save it as a unique name.
saveas Saves the preset under a different name.
Example: saveas BOOGY <enter> Commands the Omnia to save the current settings as preset BOOGY.
Non-System Parameters (paras)
paras Lists the modifiable parameters available for the current preset in a table format.
Example: paras <enter> displays the parameters for the current preset:
paravalues <index #> Lists all possible values for the parameter at the given index number.
para <para index #> <paravalue> Sets a new value for the selected parameter.
Omnia-3fm Turbo System Parameters
A 'syspara' is an Omnia-3 System parameter. The System Parameters are assigned to controls which govern
overall operation, such as Input and Output Gains, Pre-emphasis/De-emphasis, etc. These parameters would
NOT be saved with individual presets, but instead are saved using the Save To Card option in the System menu.
To obtain a list of all System parameters, you use the command 'sysparas', which lists all of the adjustable
parameters in a table format with their current setting value in brackets. Example: typing sysparas <enter>
displays the following table:
1) Input Source [AES/EBU] 2) Mono Mode [Stereo]
3) Input Phase [INVERT] 4) Input Master [+6.0dB]
5) Left Trim [+0.0dB] 6) Right Trim [+0.0dB]
8) Input LPF [15kHz] 17) Output Master [+10.0dB]
18) Left Trim [+0.0dB] 19) Right Trim [+0.0dB]
26) Headphones [-10.0dB] 33) Daypart State [ENABLED]
34) Ctrl Port Baud [19200] 48) Contrast [90]
49) Backlight [60] 50) Editing Mode [EXPERT]
51) Composite 1 [3.60 V] 52) Composite 2 [3.60 V]
53) SCA Level [-20.0dB] 54) Pilot Level [8.0%]
55) Separation [STEREO] 56) Phase Adjust [0 deg]
57) Analog Phase [1] 58) Preemphasis [75uS]
59) Deemphasis [75uS] 60) BS412 [OFF]
61) Ave. Power ['no-disp']
Setting New Syspara Values
To find the new value you wish to use for a particular Syspara:
sysparavalues <syspara index #> Lists all the possible values for any parameter.)
Example: sysparavalues 54 <enter> Displays a table listing the possible Pilot Level values.