Omnia-6ex Use and Operation Manual – V: 1.20
100
Omnia-6EX System Parameters
A 'syspara' is an Omnia 6 System parameter. The System Parameters are assigned to controls which govern overall
operation, such as Input and Output Gains, Pre-emphasis/De-emphasis, etc. These parameters would NOT be saved
with individual presets, but instead are saved using the Save To Card option in the System menu.
To obtain a list of all System parameters, you use the command 'sysparas', which lists all of the adjustable
parameters in a table format with their current setting value in brackets. Example: typing sysparas <enter> displays
the following table:
1) Input Source [Analog] 2) Mono Mode [Stereo] 3) Input Phase [Normal]
4) Input Master [0.0dB] 5) Left Input Trim [0.0dB] 6) Right Input Trim [0.0dB]
7) Master Drive [0.0dB] 17) Output Master [+10.0dB] 18) Left Output Trim [0.0dB]
19) Right Output Trim [0.0dB] 20) DAB Master [+10.0dB] 21) DAB Left [+0.0dB]
22) DAB Right [+0.0dB] 23) Analog Out [FM] 24) AES Out 1 [FM]
25) AES Out 2 [FM] 26) Headphones [-10.0dB] 33) Daypart State [Enabled]
34) Ctrl Port baud [19200] 51) Composite 1 [3.60v] 52) Composite 2 [3.60v]
53) SCA Level [-20.0dB] 54) Pilot Level [8.0%] 55) Separation [Stereo]
56) Pilot Phase [0 Deg] 58) Preemphasis [75 uS] 59) Deemphasis [75 uS]
60) BS412 [OFF] 61) Ave. Power [0.0dB] 62) Comp Range [Low]
66) Coarse Delay [8.0 Sec] 67) Medium Delay [0 ms] 68) Fine Delay [0.0 us]
69) Delay [Bypass]
Setting New Syspara Values
To find the new value you wish to use for a particular Syspara:
sysparavalues <syspara index #> Lists all the possible values for any parameter.)
Example: sysparavalues 54 <enter> Displays a table listing the possible Pilot Level values.
To set a new value for a Syspara:
syspara <syspara index #>[<sysparavalue index #>]
To reset all System parameters back to their factory defaults:
sysdefaults Restores the system attributes back to their factory defaults.
To save all System settings to the rear-panel memory card.
syssave Saves the system attributes to the Omnia PC Card.
To load the saved setting from the rear-panel memory card:
sysload Loads the system attributes from the currently inserted Omnia PC Card.