BROWSER-BASED REMOTE CONTROL
Be aware of two things when using this screen:
1. If you’re changing the IP address or password, the new information is set as soon as you
click Apply in the respective field. This may disconnect you from VOLT’s Remote Control,
until you log in again using the changed information.
If login isn’t working the way you expect after a change, use VOLT’s front panel LCD
display to verify or change the current information.
2. If you want to select a different software bank, you have to re-boot VOLT. This steprecon-
figures the DSP. Click RebootProcessoron the confirmation screen that appears. VOLT
processing is disabled during a reboot, so make sure to be on a backup air chain during this
process. In a little less than a minute, VOLT will restart with the new DSP|Core running.
VOLT processing is disabled during reboot. It will start again automatically when the rmware is loaded.
VOLT I/O congurations and processing settings are not automatically loaded when you install a
dierent DSP Core. If you want to switch VOLT’s function (EG: switching FM to AM), but might want
to re-use its settings if you restore the original function, make sure you’ve save the i/o settings as a
preset before rebooting.
I/O conguration and processing settings are preserved, even after reboot, when you cycle the power
or install a factory update of the DSP|Core rmware currently running.
If switching DSP Cores from (for example) an FM version to a downloaded AM, HD or SG version, we
recommend you load the factory IO conguration and a factory processing preset belonging to the
new DSP Core. This action will insure a all parameters are cleanly matched to the newly installed DSP
Core.
After a reboot, you’ll have to log in again to use the Remote Control. This may require
flushing your browser’s cache, or starting a new session with VOLT’s IP address.