User Manual V1.2
User Manual
-Installation
-Operation
Omniksol-15k-TL2
Omniksol-17k-TL2
Omniksol-20k-TL2
Omnik New Energy Co.,Ltd.

Questions and Answers

  • A
    Ashley MyersAug 20, 2025
    What to do if my Omnik Inverter shows a GFCI Device Fault?
    • T
      Tina SmithAug 20, 2025
      If your Omnik Inverter displays a 'GFCI Device Fault', it could be due to an issue with the inverter's GFCI detector. First, try restarting the inverter to see if that clears the fault. If the problem continues, try re-flashing the software. If neither of these steps works, the part or the entire inverter may need to be replaced.
  • T
    Tonya DoyleAug 22, 2025
    How to fix PV Volt High on Omnik Omniksol-20k-TL2 Inverter?
    • B
      Bryan HoffmanAug 22, 2025
      If your Omnik Inverter is showing a 'PV Volt High' error, it means the DC voltage is too high because of incorrect installation. To resolve this, correct the installation by removing panels. If the issue persists, try re-flashing the software. As a last resort, you may need to replace a part or the entire inverter.
  • G
    gallowayjenniferAug 25, 2025
    How to resolve PV Volt Low error on Omnik Inverter?
    • N
      ndeleonAug 25, 2025
      If your Omnik Inverter shows a 'PV Volt Low' error, it indicates that the DC voltage is below 150V. To fix this, correct the installation by adding more panels. If the problem continues, try re-flashing the software. If that doesn't work, you may need to replace a part or the inverter.
  • G
    Glenda GilmoreAug 26, 2025
    What to do if Omnik Omniksol-20k-TL2 shows No Utility error?
    • B
      ballardmelissaAug 26, 2025
      If your Omnik Inverter displays a 'No Utility' error, it means there is no AC voltage. Use a multimeter to measure the AC voltage and check the wires in the AC cable to ensure they are properly connected.
  • N
    nielsengeraldAug 28, 2025
    Why is my Omnik Inverter showing an Island Fault?
    • N
      nathanielfoxAug 28, 2025
      An 'Island Fault' on your Omnik Inverter means there's no grid or the local grid frequency isn't stable. Restart the inverter after ensuring the local grid is stable. Alternatively, you can close the protection from the inverter.
  • W
    Wendy MillerAug 29, 2025
    How to fix Ground Current Fault on Omnik Omniksol-20k-TL2 Inverter?
    • D
      Dr. Alexandra Stewart MDAug 30, 2025
      If your Omnik Inverter displays a 'Ground Current Fault', it's often due to poor grounding or can occur on rainy days. Ensure the inverter is well-grounded. You can also change it to another standard with wider protection range under authorization.
  • J
    Jamie NolanAug 31, 2025
    What causes Bus Volt High on Omnik Omniksol-20k-TL2 Inverter?
    • S
      Sarah MckinneyAug 31, 2025
      If your Omnik Inverter displays a 'Bus Volt High' error, it could be due to a wrongly test value, a software issue, or broken hardware. First, try restarting the inverter to check if that clears the fault. If the problem continues, try re-flashing the software. If neither of these steps works, the part or the entire inverter may need to be replaced.
  • L
    Lisa RuizSep 2, 2025
    What does Bus Volt Low mean on Omnik Inverter?
    • B
      Brittany JonesSep 2, 2025
      If your Omnik Inverter displays a 'Bus Volt Low' error, it could be due to a wrongly test value, a software issue, or broken hardware. First, try restarting the inverter to check if that clears the fault. If the problem continues, try re-flashing the software. If neither of these steps works, the part or the entire inverter may need to be replaced.
  • M
    Mr. Tim HawkinsSep 4, 2025
    What does Consistency Fault mean on Omnik Inverter?
    • R
      Ryan GarciaSep 4, 2025
      If your Omnik Inverter displays a 'Consistency Fault', it indicates an inconsistency in the data detected by the master and slave CPUs. Try restarting the inverter to see if that resolves the issue. If the problem persists, try re-flashing the software. If neither works, consider replacing the part or the entire inverter.
  • M
    martinlaurieSep 6, 2025
    What causes Bus Unbalance error on Omnik Inverter?
    • R
      Richard JonesSep 6, 2025
      If your Omnik Inverter displays a 'Bus Unbalance' error, it could be due to an inverter control circuit problem or the values of two rows bus capacitance differ too much. Try restarting the inverter. If the problem continues, try re-flashing the software. If neither of these steps works, the part or the entire inverter may need to be replaced.

Summary

Notes on this manual

Symbols Used

Explanation of danger, warning, caution, and notice symbols.

Preparation

Safety Instructions

Guidelines to prevent electrical shock, fire, and damage during operation.

Explanations of Symbols on Inverter

Defines various symbols used on the inverter for safety and warnings.

Product Information

Technical Data

Presents detailed specifications for different Omniksol inverter models.

Installation

Electrical Connection

Safety

Critical safety warnings for electrical connections to prevent shock.

DC Side Connection

Instructions and safety precautions for connecting the DC power input.

AC side connection

Instructions and safety precautions for connecting the AC power output.

Display

State Information

Details the different states (Wait, Normal, Fault) and their meanings.

Communication Setting

Register on monitoring website

Guides users through registering an account on the Omnik PV monitoring portal.

Troubleshooting

Omnik Omniksol-20k-TL2 Specifications

General IconGeneral
ModelOmniksol-20k-TL2
Rated Output Power20000W
Max. DC Power22000W
Number of MPPTs2
Nominal AC Voltage400V
Frequency Range50/60Hz
Power Factor>0.99
THD<3%
Cooling MethodFan
Protection Class/LevelIP65
Max. AC Power20000VA
Rated Output Current29 A
Operating Temperature Range-25°C ~ +60°C