Omnitronix DL50 User’s Manual
Page 40
Command: RESTART Function: RESTART UNIT
Syntax: RESTART
Reset the system, same as pressing the physical reset button.
Command: STATUS or ? Function: DISPLAY STATUS SCREEN
Syntax: STATUS or ?
Displays the Status screen.
Command: SUPER Function: SWITCH TO ADMINISTRATOR PRIVILEGES
Syntax: SUPER
Display a prompt for the supervisor-level access password. If the password is entered correctly,
the user level is changed to Supervisor and is granted administrator privileges.
Command: USER Function: SWITCH TO USER PRIVILEGES
Syntax: USER
Change the user level to basic user with no password prompt.
6.2 - Data Release Commands
The following settings are accessible by all users.
Command: ACCESS Function: SWITCH ACCESS FILE
Syntax: ACCESS [1|2|3|4|ALARMS]
Unmodified, displays the current access file. Modified, it switches access to the specified file.
Command: ADDLF Function: Control CR/LF translation
Syntax: ADDLF ON|OFF
Enables or disables adding of a linefeed to each incoming carriage return on data ports.
Command: CLEAR Function: CLEAR RELEASED DATA FROM FILE
Syntax: CLEAR
Delete released records in active file. Records are recoverable until overwritten (see RESTORE).