Omnitronix DL50 User’s Manual
Page 42
Command: RL Function: RELEASE DATA
Syntax: RL
Release records or data in active file.
Command: RLMODE Function: SELECT POLLING MODE
Syntax: RLMODE LINE|Xmodem|CBB
Set data polling method.
Command: TAG Function: TOGGLE LINE NUMBERS
Syntax: TAG [ON|OFF]
Enable/disable addition of line numbers to records as they are output, or display current state.
Command: WAIT Function: TOGGLE WAIT FOR NEXT COMMAND
Syntax: WAIT [ON|OFF]
Enable/disable waiting for NEXT command to release data, or display current state.
6.3 - Setup Commands
The following settings are accessible only with administrative privileges.
Command: DEFAULT Function: RESTORE FACTORY DEFAULTS
Syntax: DEFAULT
Resets all settings to factory default values, except does not change the following settings:
IP address
Subnet mask
Router address
Serial port baud rate and data format
Data alarm fields
Data alarm settings
Action queue
Does not affect record data
Command: LOADSET Function: LOAD SETTINGS FROM FILE
Syntax: LOADSET X|A
Loads settings from a PC file, using Xmodem or ASCII transfer.