E32
Fiber sensor heads
Chemical resistant fiber sensor heads
The chemical resistant fibers provide long sensor lifetime in areas with frequent
cleaning, usage of chemicals and higher temperatures.
fluoroplastic cover for highest chemical resistance
temperature resistance up to 200°C
Ordering information
Specifications
Sensor type Size Sensing distance (in mm)
*1
*1
Sensing distance measured with E3X-DA-S family in standard mode. In high resolution mode the sensing distance is approx. 30% higher.
Key feature Order code
M4 680 Fluororesin coating E32-T11U 2M
dia 5 mm 3,000 Fluororesin cover E32-T12F
dia 5 mm 1,400 Fluororesin cover E32-T14F 2M
M6 170 Fluororesin coating E32-D11U 2M
dia 6 mm 95 Fluororesin cover E32-D12F
dia 6 mm 40 Fluororesin cover E32-D14F 2M
dia 6 mm 700 Fluororesin cover
Heat resistant to 200°C
E32-T81F-S 2M
dia 5 mm 3,000 Fluororesin cover
Heat resistant to 150°C
E32-T51F 2M
Item Fluororesin coating Full fluororesin cover Full fluororesin cover and heat resistance
E32-T11U E32-D11U E32-_12F/E32-_14F E32-T51F E32-T81F-S
Permissable bending radius (in mm) 1 4 40 10
Cut to length yes no
Material Head Brass-nickel plated Fluororesin
Fiber PMMA Glass
Sheath Fluororesin coating Fluororesin cover
Degree of protection IEC60529 IP67

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron E32 and is the answer not in the manual?

Omron E32 Specifications

General IconGeneral
ModelE32
Ambient Temperature-25 to 55°C
Power Supply VoltageN/A (Fiber unit only)
Output TypeN/A (Fiber unit only)
Operating Temperature-25 to 55°C
Protection RatingIP67