A Appendices
A - 30
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
This object sets the output mode for the Sensor Amplifier with the unit number that is specified by the
index.
*1 Output 2 of the E9NC-VD0 will be EEPROM error output. This setting cannot be changed.
The previous value is retained if a measurement error occurs in Hold Mode.
The TA0 does not have output 2.
This object reads four bytes of the detection level (amount of incident light) for the Sensor Amplifier
with the unit number that is specified by the index.
The FA0, LA0, SA0, and CA0 do not use this object.
4008 + (N-1) × 80
hex
No_01 ... 30 Output Mode Setting
Subindex 0: Number of Entries
Range: 02 hex Unit: --- Default: 02 hex Attribute: ---
Size: 1 byte (U8) Access: RO PDO map: Not possible
Subindex 1: No_01 ... 30 Output Mode Setting IN1
Range: 0000 to FFFF hex Unit: --- Default: --- hex Attribute: A
Size: 2 bytes (U16) Access: RW PDO map: Not possible
Subindex 2: No_01 ... 30 Output Mode Setting IN2
Range: 0000 to FFFF hex Unit: --- Default: --- hex Attribute: A
Size: 2 bytes (U16) Access: RW PDO map: Not possible
Data
Setting
Output 1 (subindex 1)
Output 2 (subindex 2)*
1
0000 hex Normal Detection Mode Normal Detection Mode
0001 hex Area (window comparator)
detection mode
Alarm Output Mode
(FA0/LA0/FAH0)
0002 hex Differential detection mode
(FA0/EA0)
Peak detection mode (VD0)
Error Output Mode
0003 hex Hold Mode (SA0 only)
Peak bottom detection mode AND
(VD0)
Differential detection mode (FA0)
AND detection mode (CA0/MA0)
Disconnection detection output
mode (EA0)
0004 hex Peak bottom detection mode OR
(VD0)
OR detection mode (CA0/MA0)
0005 hex Difference detection mode (VD0) XOR detection mode (CA0/MA0)
0006 hex Not used. GAP detection mode (CA0/MA0)
0007 hex Not used. Rise synchronization detection
mode (MA0)
0008 hex Not used. Fall synchronization detection
mode (MA0)
0009 hex Not used. Area detection mode (MA0)
4009 + (N-1) × 80
hex
No_01 ... 30 Detection Level (4 Bytes)
Subindex 0: Number of Entries
Range: 01 hex Unit: --- Default: 01 hex Attribute: ---
Size: 1 byte (U8) Access: RO PDO map: Not possible
Subindex 1: No_01 ... 30 Detection Level (4 Bytes)
Range: 2,147,483,648 to
2,147,483,647
(80000000 to 7FFFFFFF hex)
Unit: --- Default: --- hex Attribute: ---
Size: 4 bytes (INT32) Access: RO PDO map: Possible