Lasersafetymeasuresforlaserequipmentarestipulatedbythecountryofuse.Follow
theinstructionsdescribedbelowcategorizedinfourcases.
UsageinJapan
TheJISC6802:2014standardstipulatesthesafetyprecautionsthatusersmusttake
accordingtotheclassofthelaserproduct.Thisproductisclassifiedintoclass1defined
bythisstandard.
UsageinU.S.
ThisproductissubjectedtotheU.S.FDA(FoodandDrugAdministration)laser
regulations.ThisproductisclassifiedintoClass1bytheIEC60825-1:2014standard
accordingtotheregulationsofLaserNoticeNo.56oftheFDAstandard.Thisproductis
alreadyreportedtoCDRH(CenterforDevicesandRadiologicalHealth).
AccessionNumber:1920014-001
WhenusingadeviceequippedwiththeproductintheU.S.,attachanFDAcertification
labelnearthesensormountedoncustomerequipment.
CMOSLaserSensor
ThankyouforselectingOMRONproduct.Thissheetprimarilydescribesprecautions
requiredininstallingandoperatingtheproduct.
Beforeoperatingtheproduct,readthesheetthoroughlytoacquiresufficient
knowledgeoftheproduct.Foryourconvenience,keepthesheetatyourdisposal.
PrecautionsforCorrectUse
Packagecontents
PrecautionsforSafeUse
Pleaseobservethefollowingprecautionsforsafeuseoftheproducts.
•DonotreverseconnectionofDCpowersupplypolarity.Donotconnect
toACpowersupply.
•Donotshort-circuittheload.
•NeverusethisproductwithACpowersupply.Otherwiseitmay
explode.
•Themaximumpowersupplyvoltageis30VDC.Beforeturningonthe
product'spower,makesurethatthesupplyvoltagedoesnotexceed
themaximumpowersupplyvoltage.
•Donotusetheproductinenvironmentswhereflammableorexplosive
gasesarepresent.
•Pleaseassessthesafetybeforehandwhenusingtheproductin
chemicalsand/oroilenvironments.
•Donotremodeltheproduct.
•Donottouchthemetalsurfacewithyourbarehandswhenthe
temperatureislow.Touchingthesurfacemayresultinacoldburn.
•Burninjurymayoccur.Theproductsurfacetemperaturerises
dependingonapplicationconditions,suchastheambienttemperature
andthepowersupplyvoltage.Attentionmustbepaidduring
operationorcleaning.
•Donothittheproductusingahammerforinstallation.
•Theproductmustbeinstalledwiththespecifiedtorqueorless.
ForM8connectorandPre-wiredM8connector,thepropertightening
torqueisfrom0.3to0.4Nm.
IncaseofM12Pre-wiredsmartclickconnector,manuallytightenthe
connector.
•Tighteningtorqueforthemountingholeis0.6Nmorless(M3screw).
•Donotusetheproductinambientatmosphereorenvironmentexceeding
therating.
•Outputpulsesmaybegeneratedwhenthepoweristurnedoff.Itis
recommendedtoturnoffthepoweroftheloadorloadlinefirst.
•TheextensionofthecordunderthestandardI/Omodeshouldbe100m
orless.UndertheIO-Linkmode,thelengthshouldbe20morless.
•Donotpullthecordtoostrongly.
•Besuretoturnoffthepowersupplywhenconnectingordisconnecting
thecable.
•Waitforatleast600msafterturningontheproduct'spower.
•TheproductisratedasIP67butpleaseavoidusingtheproduct
underwater,underrain,andoutdoors.
•IftheSensorwiringisplacedinthesameconduitsorductsashigh-voltage
orhigh-powerlines,inductivenoisemaycausemalfunctionordamage.
Wirethecablesseparatelyoruseashieldedcable.
•Donotusetheproductindirectsunlight.
•Donotusetheproductwherehumidityishighanddewcondensation
mayoccur.
•Donotusetheproductwherecorrosivegasesmayexist.
•Useakeylocktopreventmalfunctionifhigh-pressurewashwaterorother
substancescomeintocontactwiththebutton.
•Donotapplyhigh-pressurewashingwaterdirectlytothesensor'slight
emitting/receivingsurfacefromashortdistance.Astheantifouling
featuremaybeimpaired,keepasufficientdistancefromthelightemitting
/receivingsurface.
•Donotusetheproductatalocationsubjecttoshockorvibration.
•Touseacommerciallyavailableswitchingregulator,FG(frameground)
mustbegrounded.
•Thisproductcannotbeusedasadetectiondeviceforhumanbody
protection.
•Donotuseorganicsolvents(e.g.paintthinnerandalcohol)forcleaning.
Otherwiseopticalpropertiesandprotectivestructuremaydeteriorate.
•Besuretochecktheinfluencecausedbysurroundingenvironmentssuch
asbackgroundobjectsand/orLEDlightingbeforeusingtheproduct.
•Donotexceed100,000writingoperationsoftheEEPROM(non-volatile
memory).SettinginformationiswrittentotheEEPROMwhenathreshold
valuechange,teaching,orzeroresetisexecuted.
Instructionsheet(thissheet,Compliancesheet,Indexlist(attachedfor
IO-Linktypeonly),FDAcertificationlabel,Warninglabel
INSTRUCTIONSHEET
Disposeinaccordancewithapplicableregulations.
Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,
willresultinminorormoderateinjury,ormayresultinseriousinjury
ordeath.Additionallytheremaybesignificantpropertydamage.
Thisproductisnotdesignedorratedforensuringsafetyofpersons
eitherdirectlyorindirectly.Donotuseitforsuchpurpose.
WARNING
Donotusetheproductwithvoltageinexcessoftheratedvoltage.
Excessvoltagemayresultinmalfunctionorfire.
Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,
mayresultinminorormoderateinjuryorinpropertydamage.
CAUTION
●MeaningofSignalWords
PRECAUTIONSONSAFETY
Tosafelyuselaserproducts
Itscomponentmaybedamagedand/ordegreeofprotectionmaybedegraded.
Pleasedonotapplyhighpressurewaterintensivelyatoneplaceduringcleaning.
WARNING
WARNING
CAUTION
FDAcertificationlabel
©
OMRONCorporation
2020
AllRightsReserved.
E3AS-HL150/HL500
ThefollowingnoticeappliesonlytoproductsthatcarrytheCEmark.
Notice:
Inaresidentialenvironment,thisproductmaycauseradiointerference,
inwhichcasetheusermayberequiredtotakeadequatemeasures.
LookingintotheOutgoinglightcontinuouslymaycausevisualimpairment.
DonotlookdirectlyintotheOutgoinglight.
Caution-Useofcontrolsoradjustmentsorperformanceofproceduresother
thanthosespecifiedhereinmayresultinhazardousradiationexposure
Attention-Lʼutilisationdescommandesouréglagesoulʼexécutiondes
procéduresautresquecellesspécifiéesdanslesprésentesexigences
peuventétrelacausedʼuneexpositionàunrayonnementdangereux
Donotdisassemblethisproduct.Doingsomaycauseexposureto
thebuilt-inlightsourcewhichcandamageeyesandskin.Never
disassembleit.
Manufacturer:
OmronCorporation,
ShiokojiHorikawa,Shimogyo-ku,
Kyoto600-8530JAPAN
TRACEABILITYINFORMATION:
ImporterinEU:
OmronEuropeB.V.
Wegalaan67-69
NL-2132JDHoofddorp,
TheNetherlands
Centeroflaserprojection
Warninglabel
Model
1
UsageinChina
ThisproductisclassifiedintoClass2bytheGB7247.1:2012(IEC60825-1:2007)standard.
WhenusingadeviceequippedwiththeproductinChina,attachaWarninglabelnear
thesensormountedoncustomerequipment.
UsageincountriesotherthanU.S.andChina
ThisproductisclassifiedintoClass1bytheIEC60825-1:2014/EN60825-1:2014+A11:2021
standard.
* 5630539-9D*
Question and Answer IconNeed help?

Do you have a question about the Omron E3AS-HL500MT 2M and is the answer not in the manual?

Omron E3AS-HL500MT 2M Specifications

General IconGeneral
ModelE3AS-HL500MT 2M
Sensing Distance500 mm
Output TypePNP
Supply Voltage12 to 24 VDC
Response Time1 ms
Operating Temperature-25 to 55°C
Connection MethodPre-wired Cable
Length2 m
Compatible SeriesE3AS Series
IP RatingIP67
Cable MaterialPVC
ShieldedYes
CategoryAccessories
Connector TypeM12 connector

Summary

Instruction Sheet Overview

Traceability and Safety Information

Provides product traceability details, general safety warnings, and laser product safety guidelines.

Sensor Settings and Operations

Output Modes and Display

Teaching Procedures

Basic Teaching Methods

Details 2-point teaching and Background Reference Teaching (Normal).

Advanced Teaching and Status

Advanced Teaching Techniques

Covers Object Teaching and Background Reference Teaching (Sensitive).

Manual Adjustments and Utilities

Threshold Value Manual Adjustment

Explains how to adjust threshold values using UP/DOWN buttons.

Detailed Settings Menu Flow

Response Time and Output Configuration

Guides through setting response time, output modes, logic, and timers.

Advanced Configuration Options

ABT and Hysteresis Settings

Details ABT function, hysteresis modes, and width adjustments.

Advanced Functions and Troubleshooting

ABT and Hysteresis Functionality

Explains Automatic-Background-Tracking and Hysteresis mode functions.

Troubleshooting Sensor Errors

Lists error types, causes, and corrective actions for sensor malfunctions.