EasyManuals Logo

Omron E3AS-HL500MT 2M User Manual

Omron E3AS-HL500MT 2M
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
Forinitialthresholdvalues,referto"4-4ThresholdValueManual
Operations"(   page7).
DisplayReverse
  6-5(10page)
UP
UP
DOWN
Disp.Reverse
Off
TEACH
T
Off On
DisplayBrightness
  6-6(10page)
UP
DOWN
Brightness
Normal
TEACH
T
Normal Dark
ZeroReset
Memory
*3
  5-3(7page)
UP
DOWN
ZeroMemory
Off
TEACH
T
Off On
KeepFunction
*3
  6-7(10page)
UP
DOWN
KeepFunc.
Off
TEACH
T
Off On
TeachingSelection
(press&holdfor3s)
  6-9(10page)
UP
DOWN
Teach3sec.
Background
TEACH
T
Background Object
BackgroundReference
TeachingSelection
  6-10(10page)
UP
DOWN
Ref.Teach
Normal
TEACH
T
Normal Sensitive
HysteresisMode*3
  6-12(11page)
UP
DOWN
HysMode
Auto
TEACH
T
Auto User
Output1
Hysteresiswidth*3*6
  6-12(11
page
)
UP
DOWN
Out1Hys
10
TEACH
T
E3AS-HL150:0.0 150.0
E3AS-HL500:0 500
Output2
Hysteresiswidth*3*6
  6-12(11
page
)
UP
DOWN
Out2Hys
10
TEACH
T
E3AS-HL150:0.0 150.0
E3AS-HL500:0 500
MutualInterference
Prevention
  6-8(10page)
UP
DOWN
Interference
Channel1
TEACH
T
Channel1 Channel2 Channel3 Channel4
ABTFunction
*5
  6-11(11page)
UP
DOWN
ABTFunc.
1sec
TEACH
T
1sec 0.3sec Off 3min
Unit:mm(reference)
Unit:mm(reference)
*6.Displayedonlywhenhysteresismode=User.
*5.Displayedonlywhenbackgroundreferenceteachingselection=Sensitive.
Responsetime
Output1mode
Output1logic
Output1timermode
Output1timertime
Output2function
Output2logic
Externalinput
Output2timermode
Output2timertime
Displayselection
Advancedsettings
Displayreverse
Displaybrightness
Zeroresetmemory
Keepfunction
Mutualinterferenceprevention
Teachingselection(press&holdfor3s)
Backgroundreferenceteachingselection
ABTfunction
Hysteresismode
Output1hysteresiswidth
Output2hysteresiswidth
50ms
Single
N.O.
Off
5
Out1Invert
N.O.
LaserOff
Off
5
Standard
Off
Off
Normal
Off
Off
Channel1
Background
Normal
1sec
Auto
Item
■InitialValues
Thesearefactorysettings.
Initialvalue
HL150□ HL500□
10
10
1.0
1.0
9
*3.Notdisplayedonlywhenbackgroundreferenceteaching(sensitive)isexecuted
(output1mode=Dist+Int).

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron E3AS-HL500MT 2M and is the answer not in the manual?

Omron E3AS-HL500MT 2M Specifications

General IconGeneral
BrandOmron
ModelE3AS-HL500MT 2M
CategoryAccessories
LanguageEnglish

Related product manuals