LaserOFF/Teaching/Zeroresetselectable
Fortheappliedvoltage,referto"2-1Input/OutputCircuitDiagram"(page2). Fortheinputtime,referto"3-3ExternalInput"(page3).
Reversedpowerpolarityprotection,Outputshort-circuitprotection,andOutputreversepolarityprotection
OLEDDisplay(White),Power/Communicationindicator(Green),Operationindicator(Orange)
1.5ms/10ms/50msselectable
4unitsmax.(whenusingthemutualinterferencepreventionfunction)
Operating:-10to+50℃(withnoicingorcondensation)Storage:-25to+70℃(withnoicingorcondensation)
Operating:35to85%RH,Storage:35〜95%RH(withnocondensation)
20MΩmin.at500VDC
1,000VACat50/60Hzfor1minute
10to55Hz,1.5-mmdoubleamplitudefor2hourseachinX,Y,andZdirections
500m/s
2
for3timeseachinX,Y,andZdirections
IP67(IEC60529),IP69K(ISO20653),IP67G(JISC0920Annex1)
Pre-wiredtype:48.6×30.4×15.5mm,Connectortype:47.1×28.9×15.5mm
SUS316L
Polyamide11(PA11)
Methacrylicresin(PMMA)(Lenscover:Antifoulingcoating)
Ver1.1
COM3:230.4kbps,COM2:38.4kbps
PDsize:4byte,ODsize:1byte(M-sequencetype:TYPE2V)
COM3:1.2ms,COM2:3.5ms
Spotsize(referencevalue)*2
Lightsource(wavelength)
Powersupplyvoltage
Consumptioncurrent
35to500mm
Receiversurfaceilluminance:
Incandescentlamp:20,000lxmax.,Sunlight:25,000lxmax.atdistanceof250mm
Incandescentlamp:5,000lxmax.,Sunlight:10,000lxmax.atdistanceof500mm
Receiversurfaceilluminance:
Incandescentlamp:8,000lxmax.,Sunlight:16,000lxmax.
35to150mm
RatingsandSpecifications
8
Externalinput
Protectioncircuits
Indicator
Responsetime
Mutualinterferenceprevention
Ambientillumination
Ambienttemperature
Ambienthumidity
Insulationresistance
Dielectricstrength
Vibrationresistance
Shockresistance
Enclosureratings
Dimensions
Material
Conformitystandards
Controloutput
Sensingdistance
Standarddetectable
difference*1
Communication
specifications
Case
E3AS-HL500MN□series
E3AS-HL500MD□series
E3AS-HL500MT□series
2.5×1.5mmatdistanceof500mm 18×1.5mmatdistanceof500mm
ULCertification,CEMarking,RCM,EAC,IEC60825-1:2014(LaserClass1),FDA(LaserClass1),Ecolab,RoHs2,WEEE2
2.5×1.3mmatdistanceof150mm 8×1.3mmatdistanceof150mm
E3AS-HL500LMN□series
E3AS-HL500LMD□series
E3AS-HL500LMT□series
E3AS-HL150MN□series
E3AS-HL150MD□series
E3AS-HL150MT□series
E3AS-HL150LMN□series
E3AS-HL150LMD□series
E3AS-HL150LMT□series
NPNoutput
PNPoutput/COM2
PNPoutput/COM3
Model
Triangulation
Sensingmethod
Indicator
LenscoverandDisplay
IO-Linkspecification
Baudrate
Datalength
Minimumcycletime
■Modelstandard
Triangulation
500mm
150mm
Spot
Line
Red
Metal
NPNopencollector
PNPopencollector/COM2
PNPopencollector/COM3
HL
500
150
Blank
L
Blank
M
N
D
T
①
Mark
②
③
④
⑤
⑥
Sensingmethod
Specification
Sensingdistance
Emissionspotshape
Lightsource
Casematerial
Outputmethod
E3AS-HL□ □ □ M □ □ □ □
① ②③④⑤⑥⑦⑧ ⑨
Note:1.Altitude:Upto2000m,Pollutiondegree:3,Enclosuretype:Type1.
*1.MeasuredwithOMRON'sstandardworkpiece(Whiteceramic).
*2.DefinedbyD4σmethodatthemaximumsensingdistance.Detectionmaybeinfluencedifthereislightleakageoutsidethedefinedregionandthe
surroundingsofthetargetobjecthaveahighreflectanceincomparisontothetargetobject.Also,whendetectingaworkpiecethatissmallerthanthespot
size,acorrectvaluemaynotbeobtained.
Pre-wired
Pre-wiredM12SmartclickConnector
Pre-wiredM8Connector
M8Connctor
Specialspecification
M8Connector
2m+150/-0mm(Pre-wired)
5m+150/-0mm(Pre-wired)
0.3m+60/-0mm(Pre-wiredConnector)
Blank
‐M1TJ
‐M3J
M3
alphanumericalcharacter
Blank
2M
5M
0.3M
⑦
⑧
⑨
Connectionmethod
Optionalsuffix
Codelength
Suitability for Use
t
OMRON Corporation shall not be responsible for conformity with any standards, codes or
regulations which apply to the combination of the Product in the Buyer’s application or use of
the Product. At Buyer’s request, Omron will provide applicable third party certification
documents identifying ratings and limitations of use which apply to the Product. This
information by itself is not sufficient for a complete determination of the suitability of the
Product in combination with the end product, machine, system, or other application or use.
Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application
responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE
OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN
DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS
PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
D
OMRON Corporation
Industrial Automation Company
Contact: www.ia.omron.com
Kyoto, JAPAN
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-6023-0333/Fax: (86) 21-5037-2388
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
Regional Headquarters
Loadpowersupplyvoltage30VDCmax.(Class2),thetotalloadcurrentofthetwooutputsis100mAmax.
Residualvoltage(Loadcurrent10mAmax.:1VDCmax.,Loadcurrent10to100mA:2VDCmax.)
Opencollectoroutputtype(DependsontheNPN/PNPoutputtype)N.O.(NormallyOpen)/N.C.(NormallyClose)selectable
Redlaser(660nm)
10to30VDC,(includingripple(p-p)10%),Class2
100mAmax.
35to180mm:9mm
180to300mm:18mm
300to400mm:30mm
400to500mm:45mm
at10msec
35.0to50.0mm:1mm
50.0to100.0mm:2mm
100.0to150.0mm:4mm
at10msec
12