Maintenance
4
dpc
%n
hs
500
stnd
500
4000
shs
125
dpc
%ff
----
9999
MODE
MODE
MODE
2.
Detection Function
Changing Light Level and Response Time
per
%ff
per
%n
3. DPC Function
Stable Detection Regardless of Incident
Light Level Change
4. Timer Function
Setting Output Timer
(Two outputs are displayed for the two-output type)
UP/DOWN
UP/DOWN
14.
Inverted Display *7
Mounting Amplifier in Inverted Direction
13. Digital Display *7
Changing Digital Display in RUN Mode for Specific Purpose
6.
BANK Switching
Set values are saved for each configured bank.
8.
Percentage Tuning
Detecting Transparent or Microscopic object (Two outputs are displayed for the two-output type)
MODE
MODE
MODE
MODE
MODE
%ff
B
UP/DOWN
UP/DOWN
UP/DOWN
UP/DOWN
(IncidentLightLevelExample)
Detailed Settings
5
dflt
MODE
1. Function Selection
Enabling 6 to 17
ec%
%ff
ec%
%n
UP/DOWN
husr
37
37
UP/DOWN
15.
Eco Function *7
Saving Power Consumption
MovetoDetectionModebyholdingthebuttonfor3secondsorlonger.
16.
Hysteresis width
5.
Power Tuning Level
Changing the Target Incident Light Level (Power Tuning Level)
%n-d
10
10
----
std
A
A
p-b
bar
UP/DOWN
UP/DOWN
2
3
4
Select [Setting Mode] -> [Digital Display] to set [diSP CFdr].
Pressing the [MODE] button for 3 seconds or longer exits the SET mode.
Before Passing Right after passing
Let the workpiece pass.
Displays and retains the light intensity (maximum/minimum value) in white digital for 0.5 seconds when the workpiece passes.
1.
2.
3.
4.
Press both the [MODE] and [L/D] buttons for at least 3 seconds
to set to [SoLU on]. To release the setting, press the [MODE]
and [L/D] buttons for at least 3 seconds to set to [SoLU oFF].
Let the workpiece pass.
Passing time and light amount difference are displayed.
1.
2.
3.
Press the [MODE] and [L/D] buttons at the same time
for at least 3 seconds to exit setting mode.
4.
0
2000
Hold both for 3 sec. or longer Hold both for 3 sec. or longer
6000
4000
2000
9999
2000
1000
LightamountdifferencePassingtime
(m:msec,μ:μsec)
LightamountdifferencePassingtime
(m:msec,μ:μsec)
0m
0
500m
63
Enable/Cancel
(The same procedure)
Enable Cancel
rst
Convenient Setting Features
3
For Stable Detection Regardless of Received Light Intensity Changed due to Dust or Dirt
●Zero Reset Function
Returning Received Light Intensity Display to "0"
Change finder
Checking Received Light Intensity When Workpiece Passes at High Speed
Solution Viewer
Determining If Workpiece is Detectable
●Setting Reset
Initializing Settings
rst
●Key Lock Function
Preventing Malfunction
●User Save Function/User Reset Function
Saving/Reading Settings
E3NX-FA□□Series
Initialize all settings to the factory-set defaults.
Disables all the button operations.
* Press either of UP/DOWN.
Thethresholdalsochangesaccordingly.
The lower threshold limit is -1999.
hstd
STND Standard Mode
(a)
Off-delay Timer
Time Off
(b)
On-delay Timer
(c)
One shot
(d)
On Off-delay Timer
DPC ON
SHS Super High-speed Mode
SHS2 Super High-speed Mode
SHS2 mode is set only
for E3NX-FA11-5.
GIGA Giga Mode
HS
High-speed
Mode
DPC OFF
%n
ptun
MODE
7.
Power Tuning ON/OFF Setting
To Turn ON/OFF the Light Amount Adjustment at Tuning
UP/DOWN
Powertuning
adjustmentON
PercentagetuningON
Percentage
tuningOFF
std
9.
Output 1 Mode
Output mode for the output 1 is changed.
MODE
UP/DOWN
Normal
detectionmode
std
alrm
10.
Output 2 Mode
Output mode for the output 2 is changed.
MODE
UP/DOWN
Alarmoutputmode
err
Erroroutputmode*1
Normal
detectionmode
Basicsetting
Detailedsetting
Threshold
/Receiving
light amount
Normal
Reverse
Ecofunction
OFF
EcofunctionON
EcofunctionLO
Standard
setting
Usersetting
fd
f
MODE
BANK1
BANK2 BANK3 BANK4
ban
B
T
T
T
T
Off-delay Timer
Holds the output ON for
detection by PLC when
the detection time is too
short.
On-delay Timer
Delays the output ON
after detection.
No Incident Light
Incident Light
No Incident Light
Incident Light
No Incident Light
Incident Light
No Incident Light
Incident Light
ON
OFF
ON
OFF
L-ON
D-ON
ON
OFF
ON
OFF
L-ON
D-ON
Tb
Ta
Tb
ON
OFF
ON
OFF
L-ON
D-ON
Ta
(a)
(b)
One-shot Timer
Keeps the output ON for
a specified time regardless
of the workpiece size
variations.
T
T
ON
OFF
ON
OFF
L-ON
D-ON
(c)
ON/OFF-delay Timer
Sets both OFF-delay Timer
and On-delay Timer.
(d)
ban
ban ban
per
The display reverses.
Threshold and light intensity are displayed on
green digital and white digital respectively.
The OUT Selection Indicators show items
for Output1/Output 2 individually for each output.
A
The DPC indicator turns ON
when the DPC function is
effective.
●DPC Function
Time
内部受光量
Internal Incident Light Level
Incident Light
Level
Displayed Incident Light Level
Threshold
Level
Stabilizes the displayed
incident level by
correcting internal
incident level changes.
Smart
Tuning
SET
mode
Run Select
DPC Function
ON
Refer to "
Settings".
Hold both for 3 sec. or longer
Hold both for 3 sec. or longer
Hold both for 3 sec. or longer
Ratings and Specifications
4-2
*2.Detailsoninputsareasfollows:
*2-1Inputtimeis25ms(ON)/(OFF)onlywhen(intUnE)or(inPtUn)inputisselected.
NPNoutput
PNPoutput
Contactinput(Relayorswitch)
ON:Shortcircuitto0V(Outflowcurrent:1mAmax.)
OFF:OpenorshortcircuittoVcc
ON:ShortcircuittoVcc(Sinkcurrent:3mAmax.)
OFF:Openorshortcircuitto0V
Non-contactinput(Transistor)
ON:1.5Vmax.(Outflowcurrent:1mAmax.)
OFF:Vcc-1.5VtoVcc(Leakagecurrent:0.1mAmax.)
ON:Vcc-1.5VtoVcc(Sinkcurrent:3mAmax.)
OFF:1.5Vmax.(Leakagecurrent:0.1mAmax.)
Inputtime*2-1
ON:9msmin.
OFF:20msmin.
Approx.60g/
Approx.20g
-
Approx.60g/
Approx.20g
-
Approx.115g/
Approx.75g
Approx.200g/
Approx.160g
Approx.115g/
Approx.75g
-
Approx.115g/
Approx.75g
Approx.200g/
Approx.160g
Approx.60g/
Approx.20g
-
Approx.60g/
Approx.20g
-
Model
NPNoutput
PNPoutput
Controloutput
Externalinput*2
Connectionmethod
Lightsource(Wavelength)
Powersupplyvoltage
Powerconsumption*3
Controloutput
Protectioncircuit
MaximumconnectableUnits
Numberofunitsformutual
interferenceprevention*4
BankSwitchSetting
AutoPowerControl(APC)
Ambientillumination
Surrounding
airTemperaturerange*5
Ambienthumidityrange
Altitude
Installationenvironment
Insulationresistance
Dielectricstrength
Vibrationresistance
Shockresistance
Weight
(packed
state
/sensor)
Materials
E3NX-FA11
E3NX-FA41
1
-
Pre-wired
Red4-elementLED(625nm)
10to30VDC,includingripple(p-p)10%
Powersupplyvoltage24V:
【Standardtype】Normalmode:840mWmax.(Currentconsumption35mAmax.)
EcofunctionON:650mWmax.(Currentconsumption27mAmax.)EcofunctionLO:750mWmax.(Currentconsumptionat31mAmax.)
【Advancedfunctiontype】Normalmode:920mWmax.(Currentconsumption38mAmax.)
EcofunctionON:680mWmax.(Currentconsumption28mAmax.)EcofunctionLO:800mWmax.(Currentconsumptionat33mAmax.)
【Infraredtype】Normalmode:1080mWmax.(Currentconsumption45mAmax.)
EcofunctionON:920mWmax.(Currentconsumption38mAmax.)EcofunctionLO:1020mWmax.(Currentconsumptionat42mAmax.)
Loadpowersupplyvoltage:30VDC,opencollectoroutputtype(dependsontheNPN/PNPoutputformat)
Loadcurrent:100mAmax.for1to3unitsuse,20mAmax.for4ormoreunitsconnected
Residualvoltage:Loadcurrentlessthan10mA:1Vmax.,loadcurrent10to100mA:2Vmax.
Off-statecurrent:0.1mAmax.
Powersupplyreversepolarityprotection,outputshort-circuitprotectionandoutputincorrectconnectionprotection
30units
10units Note:2unitswhenthedetectionmodeissettoSuperHighSpeedmode(SHS),andforothermodels,
themutualinterferencepreventionfunctionisdisabled.
SelectablefromBANK1-4(BANK1and2canbeswitchedbyexternalinput.)
Provided(Alwayseffective)
IlluminationintensityIncandescentlamp:20,000lxmax./Sunlight:30,000lxmax.
Operating:1to2amplifiersconnected:−25℃to55℃,3to10amplifiersconnected:−25℃to50℃,
11to16amplifiersconnected:−25℃to45℃,17to30amplifiersconnected:−25℃to40℃
Storage:−30to70(withnoicingorcondensation)
Operatingandstorage:35to85%(withnocondensation)withinthesurroundingairtemperaturerangeshownabove
2000mmax.
Pollutiondegree3(asperIEC60947-1)
20MΩmin.(at500VDC)
1,000VAC,50/60Hz,1minute
10to55Hzwitha1.5mmdoubleamplitudefor2hrseachinX,YandZdirections
500m/s
2
,for3timeseachinX,YandZdirections
Approx.115g/
Approx.75g
Approx.200g/
Approx.160g
Caseandcover:Polycarbonate(PC),Cable:PVC
E3NX-FA21
E3NX-FA51
2
1
Pre-wired
E3NX-FA6
E3NX-FA8
1
-
Wire-saving
connector
E3NX-FA7
E3NX-FA9
1
1
Wire-saving
connector
E3NX-FA7TW
E3NX-FA9TW
2
-
Wire-saving
connector
Cablelength2m
Cablelength5m
Approx.65g/
Approx.25g
-
E3NX-FA24
E3NX-FA54
1
1
M8connector
Approx.65g/
Approx.25g
-
-
E3NX-FA54TW
2
-
M8connector
Hold button for 3 seconds or longer to enter SET mode.
MODE
SET mode provides the following function settings. The initial
display shown after transition from one function to another
represents the factory default.
UP/DOWN
Use button to set the power tuning level.
(100 to 9999 in 1 steps; the initial value: 9999)
UP/DOWN
Use button to set the time.
Function Selection: [ ]
Function Selection: [ ]
Press button in [ ] menu, then use
button to set the percentage tuning level.
(-99% to 99% in 1% steps; the initial value: -6%)
MODE
UP/DOWN
Lightamountdifference
Threshold
Passingtime
(msorμs)
func
func
Detectionfunction
Responsetime
Lightquantity
HS
250μs 60μs1ms 16ms OneOutput:30μs
TwoOutput:32μs
1(reference)
STND
x1
GIGA
x8
SHS SHS2*
x0.25 x0.25
Besuretocheckthestabilityofoutputs
asthereisapossibilityofchattering.
Thehysteresiswidthcanbesetbypressingthebuttoninthemenu
of"husr"andthenpressingthebutton.(0to9999,incrementsof1)
MODE
UP/DOWN
MODE
%n
UP/DOWN
17. WritingtoEEPROM*7
ON
OFF
Thesettingsthathavebeenchangedbyanexternalinput
with"oFF"willnotbeoverwrittentopreventEEPROM
fromreachingitslifespan(1,000,000writings).
cfdr
*3.Powerconsumption
*4.Thetuningwillnotchangethenumberofunits.
TheleastunitcountamongthemutualinterferencepreventionunitsofE3NXandE3NC.
Checkthemutualinterferencepreventionunitcountandresponsespeedofeachmodel.
UseoftheDPCfunctionwiththrough-beammodel
orregressivereflectionmodelisrecommended.
MODE
After pressing the button,
ExecutingDPCfunction/
smarttuningreleasesthe
zeroreset.
Whensmarttuningisinerror/
maximumsensitivitytuningisexecuted/
the1stpointofthepositiontuningissmaller/area
detectionmode,theDPCfunctionisdisabled.
(Referencevalue)
ch
ec%
l%
Ecoon
The indicators (green digital and white digital) turn OFF.
They turn ON for approx. 10 seconds and then turn OFF
by button operation.
Eco Lo
They turn ON for approx. 10 seconds and then
the indicators (All) turn ON
with low brightness.
*5.Whenthenumberofconnectedunitsis11ormore,theambienttemperatureislessthan50℃.
h
Suitability for Use
s
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer’s application or use of the Product. At Buyer’s request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
Oct, 2014
D
OMRON Corporation
Industrial Automation Company
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Regional Headquarters
Onlythemodelwithtwo-outputtype
(a)Toseethereserveofthelight
intensitylevelforthethreshold
(b)Tosetthethresholdwitha
microscopicobjectorfast-movingobject
(c)Toseetheintuitiveand
easytofollowdisplay
(d)Toadjustthebeam
(e)ToknowtheCHnumberwhentwo
ormoreunitsconnected
(f)Toseethereceivedlightintensity
whenworkpiecepassesathighspeed
150p
(a)
2000
8000
(b)
(c)
3000
3500
(d)
3000
(e)
9999
2000
(f)
Threshold
Received light intensity ratio
Peak receiving light amount
Bottom receiving light amount
Threshold
120% 100% 80%
Peak receiving light amount
Receiving light amount
CH number
Receiving light amount
Threshold
Received light amount after passing
Thechangefinderisnot
displayedin[SettingMode].
Iftheproductisthereflective
type,thelocalmaximumvalueis
displayedbysettinglight-on.Ifit
isthethrough-beamtype,the
localminimumvalueisdisplayed
bysettingdark-on.
Powertuningadjustmentonpower-up
ptun
p%n
ptun
%ff
PowertuningadjustmentOFF
Differentialdetectionmode*2*3
Differentialdetectionmode
*2,*3
area
Areadetectionmode*1
MODE
UP/DOWN
Alarm Output Mode: After pressing the button,
press the button to set alarm output level. (0 to 100p
in 1p steps; the initial value: 50p) On-delay of 300ms is
applied. Error output mode: Output when a DPC error or
EEPROM error occurs.
Ifthe""menuisselected,responsetimecan
besetupcontinuously.
1:250μs,2:500μs,3:1ms,4:10ms,5:100ms
[rst]
MODE MODE
[ ]
UP/DOWN
[rst]
[rst user
]
yes
MODE MODE
UP/DOWN
[ ] [ ]
UP/DOWN
UP/DOWN
MODE
MODE
User Save Function
User Reset Function
(Two outputs are displayed for the two-output type)
Set the hysteresis width by initial value. Hysteresis width is
provided for threshold to prevent the judgment output from
becoming unstable near the boundaries.
(1 to 9999ms in 1ms steps; the initial value: 10ms
Errorrange
:
0.1ms
)
●
Troubleshooting
Problem Cause Remedy
Remedy
Cause
Error Name / Display
●
Error Display
2000
4000
Troubleshooting
4-1
DPC Error
*1
Load short circuit detection error
Lock ON
*2
Refer to "
Detailed Settings".
Cancel the key lock function.
*3
Check wiring and connector connection
again.
*4
The key lock
function enabled
Failed internal data
read/out
Over current flowing
to the control output
In the sensor OFF or emission OFF state,
setting initialization and user resetting are
disabled. Cancel the sensor OFF or
emission OFF state before trying again.
While writing in the EEPROM, setting
initialization and user resetting are disabled.
Wait for a couple of seconds and try again.
Setting change or
writing to the
EEPROM are
disabled.
*4
Refer to "
Convenient Setting Features"
*1
Refer to "1-2 Input/Output Circuit Diagram"
*3
Refer to "1-3 Mounting Amplifier Unit"
*2
Refer to "2-3 Smart Tuning "
*4
Refer to "1-2 Input/Output Circuit Diagram"
and "4-2 Ratings and Specifications"
*1
The DPC indicator blinks.
*3
Refer to "
Convenient Setting Features"
e-st
Check the wiring, connector connection, power supply
voltage and power supply capacity again.
*1
Nothing is shown
on the indication.
No power supplied or the
cable broken
Turn OFF Eco mode.
*2
Nothing is shown on
the digital indication.
Eco mode is ON.
Check the Amplifier Units mounted in a group and
turn ON the power again.
*3
The OUT indicator
blinking
Mutual interference or
other reason
Cancel the zero reset function.
*4
Incident light level displayed
in a negative value
The zero reset function is
enabled.
The receiving light intensity display is
stabilized using the DPC function.*4
The light intensity
level display changes.
Affected by dust or dirt, temperature
change, vibration, etc.
Reset the settings.
*4
Lost tracking of
the settings made
Setting GIGA Mode increases emission
power and light intensity.
*2
Sensing/Detection
not possible
despite the
minimum threshold
level
Detection set to a small
light level mode Dust or
dirt influences
Wipe the dust off the Fiber Unit detection
surface or other relevant areas and recover
the original incident light level. Then, perform
Smart Tuning.
*2
The incident light level
has deteriorated due
to dust or dirt.
E3NX-FAH11
E3NX-FAH41
1
-
Pre-wired
InfraredLED(870nm)
E3NX-FA11-5*1
-
1
-
Pre-wired
E3NX-FAH6
E3NX-FAH8
1
-
Wire-saving
connector
Type Standard Advancedfunction Infrared
Standardtype InfraredtypeAdvancedfunctiontype
shs2
125
*1.ThistypecanpreventmutualinterferencefortwounitsintheSHS2mode.
Refertodifferentialdetectionmodeofoutput1mode.
(OnlythemodelwithStandardandAdvancedfunctiontype)
(OnlythemodelwithStandardandAdvancedfunctiontype)
Powersupplyvoltage10Vto30V:
Normalmode:990mWmax.
(Powersupplyvoltage30V:Currentconsumption33mAmax./
Powersupplyvoltage10V:Currentconsumption65mAmax.)
EcofunctionON:780mWmax
.(Powersupplyvoltage30V:Currentconsumption26mAmax./
Powersupplyvoltage10V:Currentconsumption42mAmax.)
EcofunctionLO:840mWmax.
(Powersupplyvoltage30V:Currentconsumption28mAmax./
Powersupplyvoltage10V:Currentconsumption45mAmax.)
Powersupplyvoltage10Vto30V:
Normalmode:1020mWmax.
(Powersupplyvoltage30V:Currentconsumption34mAmax./
Powersupplyvoltage10V:Currentconsumption67mAmax.)
EcofunctionON:810mWmax.
(Powersupplyvoltage30V:Currentconsumption27mAmax./
Powersupplyvoltage10V:Currentconsumption44mAmax.)
EcofunctionLO:870mWmax.
(Powersupplyvoltage30V:Currentconsumption29mAmax./
Powersupplyvoltage10V:Currentconsumption48mAmax.)
Powersupplyvoltage10Vto30V:
Normalmode:1260mWmax.
(Powersupplyvoltage30V:Currentconsumption42mAmax./
Powersupplyvoltage10V:Currentconsumption80mAmax.)
EcofunctionON:1050mWmax.
(Powersupplyvoltage30V:Currentconsumption35mAmax./
Powersupplyvoltage10V:Currentconsumption60mAmax.)
EcofunctionLO:1140mWmax.
(Powersupplyvoltage30V:Currentconsumption38mAmax./
Powersupplyvoltage10V:Currentconsumption70mAmax.)
User Resetting and User Saving are applicable to the bank
common setting only.
e-me
Theasterisk*representsanumber.
*
EEPROMerror
Settingchangeexecutionerror
*isinitorUSEr
err
*
MODE
tune
ptun
UP/DOWN
SensorOFF*6
0rst
%ff
MODE
11.
External Input
A type of external input is changed.(Only the model with External Input type) *4 ,*5, *7
InputOFF
Tuning Powertuning
EmissionOFF
Zeroreset
BANKswitching
OFF:1,ON:2
12.
Batch tuning setting
Tuning multiple amplifiers together *4,*7
MODE
allt
UP/DOWN
Batchpercenttuning Batchpowerpercenttuning
per
allt
BatchtuningfunctionOFF
pper
allt
*1. The relationship between the control output and
output switch during area detection mode is as
follows:
*2. be sure to set the detection function to HS first
when setting the differential detection mode,
*3. It detects if the relative value of the received light
intensity change of the configured response time is
larger than the threshold. The variation of the
received light intensity of the response time that
has been set to the white digital is displayed. The
detection function setting becomes disabled when
the differential function is enabled. Smart tunings
other than power tuning are disabled.
*5. When performing a percentage tuning on the external input, turn ON the 8. Percentage
Tuning and turn OFF the 12. Batch Tuning Setting.
*6. Emitter is turned OFF and output is turned OFF due to the external input signal during
the sensor OFF setting. The sensor OFF state can be released by the external input
signal.
*7. It is a common setting for BANK. Only one set value can be set between BANK1 to
BANK4.
External input setting: tuning, batch tuning setting: Tuning starts with the signal input time of
25 ms or more with the setting not oFF.
External input setting: Tuning starts with the signal input time of 25 ms or more during
power tuning.
External input setting: At the time of zero reset
External input setting: Operation starts with the signal input time of 25 ms or more with
emitter OFF, BANK switch and sensor OFF, and stops by releasing the signal.
*4. The signal input time is as follows:
External input setting: tuning, batch tuning setting: OFF
Hi
Lo
ON
OFF
ON
OFF
Light ON
Control output
Light ON
Control output
Point 1
Less than 3 sec.
3 sec. or longer and less than 7 sec.
7 sec. or longer
Less than 3 sec.
2-point tuning
Maximum Sensitivity Tuning
Full Auto Tuning
Position Tuning
Point 2
Less than 3 sec.
-
-
3 sec. or longer
Zero reset
Enable
Less than 3s
Cancel
3s or longer
Light intensity
Turn ON the power again. Reset the settings
if the error is not corrected.
3
If the error remains, the error is caused by
memory failure such as rewrite count
exceeded. Please replace the amplifier unit.
IfothersthanoFFisselected,thepercentagetuningsettingdisplayremains.
Forbatchtuning,selectTuningfor11.ExternalInput.
(OnlythemodelwithExternalInputtype)
Solution Viewer cannot be used when SHS Super High-speed Mode is selected for Detection Function, and Area
Detection Mode for Output 1 Mode.

Questions and Answers: